Installation Manual
Table Of Contents
- Table of Contents
- Introduction
- 1.1 How to use this Manual
- 1.2 Specifications and Features
- 1.3 Compatible Wireless Devices
- 1.4 Batteries
- PC5132 Set up & Wiring
- 2.1 Unpack the PC5132
- 2.2 Choose a Mounting Location for the PC5132
- 2.3 Antennas
- 2.4 Connect the PC5132 Receiver
- 3.1 A Note about Electronic Serial Numbers
- 3.2 Enrolling Wireless Devices (WLS904NB433, WLS907NB433)
- 3.3 Enroll & Program Wireless Keys (WLS909NB433) 5
- 3.4 Identified Wireless Keys
- Other Programming
- 4.1 Program Zones and Partitions
- 4.2 Enable PC5132 Supervision
- 4.3 Enable Supervision of Wireless Zones
- 4.4 Jamming Signal Detection
- 4.5 PC5132 Software Default
- 4.6 Deleting Wireless Devices
- Testing & Mounting
- 5.1 Test the Reception of Wireless Devices
- 5.2 Mount the PC5132 and Wireless Devices
- Additional Notes
- 6.1 Trouble Conditions
- 6.2 Jamming Signal Detection
- 6.3 Wireless Zone Low Battery Transmission
- Troubleshooting
- Programming Worksheets
- Index
9
O T H E R P R O G R A M M I N G
RF Jamming Detection Sensitivity
There are two RF jamming detection settings for sensitivity: Normal and
Sensitive. Use the Sensitive setting for installations in rural areas, or for
installations where the zones are located at the far end of their range from the
PC5132 receiver. Use the Normal setting for all other applications.
To change the RF jamming detection sensitivity:
1. Enter [✱][8][Installer Code] to enter Installer Programming.
2. Enter [804] to enter the PC5132 Module Programming.
3. For Sensitive detection, turn ON section [90], option [6]. For Normal
detection, turn OFF section [90], option [6]. (Option is set to OFF by
default.)
4. To exit press [#].
4.5 PC5132 Software Default
Returning the PC5132 programming to factory default settings is a quick way to
remove all the enrolled devices from the system and reset all the programming
in section [804].
NOTE: Performing this procedure will not change any programming sections
except [804]. Resetting the control panel to factory default settings will
not
re-
turn the PC5132 module to factory default settings.
To restore the PC5132 programming to the factory default settings:
1. Enter [✱][8] [Installer’s Code].
2. Enter programming section [996].
3. Enter the Installer’s Code, followed by [996] again. The software for the
PC5132 will be restored to its factory default settings.
4. To continue programming the unit, exit installer’s programming by
pressing [#] and then re-enter installer’s programming by entering [✱][8]
[Installer’s Code].
For instructions on restoring the default programming of the control panel or any
other connected module, see your system Installation Manual.
4.6 Deleting Wireless Devices
To remove a wireless device from the system, follow the guideline for enrolling
a wireless device (see section 3.2). Program the ESN as [000000]. The wireless
device for the zone will be removed.
NOTE: You may need to remove power from the panel in order to clear troubles
caused by deleted zones.
Now that you have completed all PC5132 related programming, you can test