• W A R N I N G • This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. Installation Manual PC5132-433 Please see page ii for a description of new features for the PC5132-433 v3.12. Version 3.
WARNING Please Read Carefully Note to Installers This warning contains vital information. As the only individual in contact with system users, it is your responsibility to bring each item in this warning to the attention of the users of this system. System Failures This system has been carefully designed to be as effective as possible. There are circumstances, however, involving fire, burglary, or other types of emergencies where it may not provide protection.
Table of Contents Introduction 1.1 1.2 1.3 1.4 PC5132 Set up & Wiring 2.1 2.2 2.3 2.4 10 Test the Reception of Wireless Devices ........................................................... 10 Mount the PC5132 and Wireless Devices ........................................................ 11 Additional Notes 6.1 6.2 6.3 7 Program Zones and Partitions ............................................................................ 7 Enable PC5132 Supervision ....................................................
T hank you for purchasing the PC5132 Wireless Receiver. This product is the result of several years of development and will allow you to connect up to 8 wireless detection devices to the PC585, PC1565 and PC5008, and up to 32 detection devices to the PC5015. The PC5132 uses 433 MHz.
Introduction S E C T I O N 1 This manual describes how to install, program and maintain the PC5132. Before you install the PC5132 module, you should have completed the following steps in your system installation: 1. Plan the installation and wiring of the security system (see your system Installation Manual) 2. Install the control panel, and install and enroll at least one keypad to use for programming. 3. Install and enroll any hardwired zone expander modules (PC5108) you plan to use.
I N T R O D U C T I O N 1.3 Compatible Wireless Devices Please refer to the Instruction sheets of the following devices for more information. The PC5132 v3.12 can receive signals from the following devices: • WLS904NB433 Motion Detector • WLS907NB433 Universal Transmitter • WLS909NB433 Wireless Key 1.4 Batteries The wireless devices are designed to use only Energizer Alkaline batteries (by Eveready). NOTE: Do not use other brands of batteries. Using any other brand may affect system operation.
PC5132 Set up & Wiring S E C T I O N 2 This section describes how to set up and wire the PC5132 module. 2.1 Unpack the PC5132 Check that the following parts are in your PC5132 package: · PC5132 PCB · PC5132 plastic cabinet 2.2 Choose a Mounting Location for the PC5132 NOTE: Mount the PC5132 receiver and wireless devices after you have done placement tests with the wireless devices (see sections 5.1 and 5.2).
Enrolling Wireless Devices S E C T I O N 3 This section describes how to enroll wireless devices (WLS904NB433, WLS907NB433), and wireless keys (WLS909NB433). For more information on these devices, read the instruction sheet included with each device. 3.1 A Note about Electronic Serial Numbers An electronic serial number (ESN) is printed on the back of each wireless device. ESNs are used to enroll the wireless devices with the PC5132 receiver.
W I R E L E S S D E V I C E S 3.3 Enroll & Program Wireless Keys (WLS909NB433) For wireless keys to work on the system, you need to enroll them and then program the function buttons. Wireless keys are not assigned to zones and require no zone programming. You can enroll up to 16 wireless keys on the system. Enroll Wireless keys 1. At a system keypad, enter [✱][8][Installer’s code] to go to the Installer’s Programming section. 2. Enter programming section [804]. 3.
W I R E L E S S D E V I C E S 4. For each of the 4 function buttons, enter the 2-digit number of the function you want to select. See the programming worksheets for a list of function key options. 5. Record your programming choices in the worksheets in the back of the manual. 6. To exit press [#]. 3.
Other Programming S E C T I O N 4 4.1 Program Zones and Partitions Now that you have enrolled the wireless devices, you should complete all zone programming on the system. Although the exact programming required varies depending on which control panel the PC5132 is connected to, you should check that the following programming areas are completed correctly for each wireless zone: • Enable zones and/or assign zones to one or more partitions (programming sections [201]-[209]).
O T H E R P R O G R A M M I N G 4.3 Enable Supervision of Wireless Zones NOTE: (for PC501X v1.x control panels only) In order for wireless zones to be supervised, you must enable Double End of Line (DEOL) supervision in the PC5015 control panel. For more information, refer to your Installation Manual. NOTE: (PC501X, PC5008, PC1565, PC585 v2.
O T H E R P R O G R A M M I N G RF Jamming Detection Sensitivity There are two RF jamming detection settings for sensitivity: Normal and Sensitive. Use the Sensitive setting for installations in rural areas, or for installations where the zones are located at the far end of their range from the PC5132 receiver. Use the Normal setting for all other applications. To change the RF jamming detection sensitivity: 1. Enter [✱][8][Installer Code] to enter Installer Programming. 2.
Testing & Mounting S E C T I O N 5 5.1 Test the Reception of Wireless Devices It is very important to test the proposed placement of each wireless device before it is mounted. Following these steps will test the signal strength between the PC5132 and the wireless devices. You can test all of the devices together (global placement testing) or test each device individually. To test all the devices together, see Testing All Wireless Devices Together.
T E S T I N G & M O U N T I N G 7. Go to the next device to be tested and activate it until the test result is displayed/sounded. NOTE: Wait until the placement test of one device is shown/sounded before beginning to test the next device. Continue to test the devices until both the PC5132 and the devices are in good locations. If several wireless devices produce BAD test results, you may need to move the PC5132 to a better location. (See section 2.
Additional Notes S E C T I O N 6 6.1 Trouble Conditions The control panel always watches for possible trouble conditions. If a trouble condition occurs, the keypad “Trouble” light will turn on and the keypad will beep. Press [✱][2] to display the trouble conditions. The following trouble conditions apply to the PC5132 and/or any enrolled devices. For a description of all troubles, please see your system Installation Manual.
Troubleshooting S E C T I O N 7 1. When I enter the 2-digit zone number when adding a wireless device, the keypad gives me a long beep. You cannot enter ESNs unless a PC5132 wireless receiver is connected to the Keybus. See section 2 for instructions on setting up and wiring the PC5132 module. 2. I have entered the ESN for the device but when I violate the device, the zone does not show open on the keypad.
Programming Worksheets [804] 5132--433 Wireless Expansion Programming • 6-digit entry is required. See Section 3.1 “A note on Electronic Serial Numbers” for details on programming 6-digit serial numbers.
P R O G R A M M I N G W O R K S H E E T Wireless Key Serial Numbers Default = 000000 [41] Key 01 l_____l_____l_____l_____l_____l_____l [42] Key 02 l_____l_____l_____l_____l_____l_____l [43] Key 03 l_____l_____l_____l_____l_____l_____l [44] Key 04 l_____l_____l_____l_____l_____l_____l [45] Key 05 l_____l_____l_____l_____l_____l_____l [46] Key 05 l_____l_____l_____l_____l_____l_____l [47] Key 07 l_____l_____l_____l_____l_____l_____l [48] Key 08 l_____l_____l_____l_____l_____
P R O G R A M M I N G W O R K S H E E T S Partition 1 Wireless Key Options Default = 00 [59] Function Key 1 Function Key 2 l____l____l Function Key 3 l____l____l l____l____l Function Key 4 l____l____l l____l____l Function Key 3 l____l____l l____l____l Function Key 4 l____l____l Partition 2 Wireless Key Options [60] Function Key 1 Function Key 2 Supervision [81] Wireless Supervisory Window l____l____l Default = 10 The window is programmed in 15 minute increments.
P R O G R A M M I N G W O R K S H E E T S [84] Zone Device Supervision Options (17-24) Default = ON Option ON Option OFF l________l Option 1 Zone 17 Supervision enabled Disabled l________l Option 2 Zone 18 Supervision enabled Disabled l________l Option 3 Zone 19 Supervision enabled Disabled l________l Option 4 Zone 20 Supervision enabled Disabled l________l Option 5 Zone 21 Supervision enabled Disabled l________l Option 6 Zone 22 Supervision enabled Disabled l
Index A G R add device 4 wireless key 4 antenna 1 global placement test 10 removing device 9 module 7 RF jamming 8, 12 B batteries replacing 12 type 2 buttons programming 5 I individual placement test 11 interference 3 J jamming signal detection 8, 12 C K connect Keybus 3 receiver 3 Keybus D default module 9 panel 9 delete device 9 devices 2 adding 4 removing 9 distance from control panel 1 E electronic serial number 4 enroll device 4 PC5132 7 wireless key 4 ESN 4 F factory default 9 frequenc
LIMITED WARRANTY Digital Security Controls Ltd. warrants the original purchaser that for a period of twelve months from the date of purchase, the product shall be free of defects in materials and workmanship under normal use. During the warranty period, Digital Security Controls Ltd. shall, at its option, repair or replace any defective product upon return of the product to its factory, at no charge for labour and materials.
© 2000 Digital Security Controls Ltd., Toronto, Canada Tech. Line: 1-800-387-3630 • www.dscgrp.