Product specifications
Assigning an IP Address
6-2 Configuring the Module in a DIGITAL MultiSwitch 900
Assigning an IP Address
After installing the module in a DIGITAL MultiSwitch 900, connecting the cables, and
assigning an IP address, you need to configure the module. Do this using one of the
following methods:
• A Telnet session to access the command line interface
• Through the command line interface, which is accessed through a terminal
connected to the setup port on the DIGITAL MultiSwitch 900
• Through clearVISN MultiChassis Manager
To perform a Telnet session, you must assign an IP address. To do this, complete the
following steps:
Step Action
1 Install the module into a slot on the DIGITAL MultiSwitch 900.
2 Redirect the DIGITAL MultiSwitch 900 Chassis Manager setup port to
the VNswitch 900FX slot.
3 Select the IP Configuration option from the menu.
4 Set the in-band IP address.
5 Set the default gateway, if necessary.
6 Return to the VNswitch 900FX INSTALLATION MENU and select
[2] Restart with Current Settings.
7 Open a Telnet session into the module from the management station for
further configuration. The system displays copyright statements and the
following prompt:
After the system prompt (*) appears, refer to the DIGITAL VNswitch
900 Series Switch Management for further configuration information.