Specifications
XR6/XR10 Programming Guide Digital Monitoring Products
17
9 - STOP
9.1 STOP
At the STOP prompt, pressing any Select key allows you to exit the Programmer.
When selected, the panel performs an internal reset and exits the programmer.
The Stop function causes the following to occur:
• The system is DISARMED
• The panel's Status List is CLEARED
During the Stop function, all keypad displays are momentarily blank for two
seconds. Once the programming function is terminated, the keypads return to the
Status List display.
10.1 SET LOCKOUT CODE
Pressing COMMAND at the Stop prompt displays SET LOCKOUT CODE. This feature
allows you to program a special code that will then be required to gain access to
the panel's internal Programmer through the keypad.
Changing the Lockout Code
You can change this code at any time to any combination of numbers from 1 to 5
digits long (1 to 65535). Leading zeros must not be used for the lockout code.
1. Press a Select key. The display changes to ENTER CODE: -.
2. Enter a 1 to 5 digit code (do not enter a number higher than 65535). Press
COMMAND.
3. Enter the new Lockout Code again. Press COMMAND. The keypad display
changes to CODE CHANGED.
Once you have changed the code, it is important that you write it down
somewhere and store it in a safe place. Lost lockout codes require the panel to be
sent back into DMP for repair. You may cancel a Lockout Code by entering 00000
at the Set Lockout Code command.
Lockout Code restriction
Do not set a Lockout Code higher than 65535.
10 - SET LOCKOUT CODE
STOP
SET LOCKOUT CODE