Specifications

XR6/XR10 Programming Guide Digital Monitoring Products
5
3 - COMMUNICATION
3.1 COMMUNICATION
This section allows you to configure the communication settings for the panel.
After choosing the Communication type, continue through the remaining options.
3.2 COMMUNICATION TYPE
Specifies the communication method the panel uses to contact the receiver. Press
any Select key to display the following communication options:
NONE - For local systems. Selecting this ends Communication programming.
DD - Digital Dialer communication to DMP SCS-1 or SCS-105 Receivers.
4-2 - 4-2 communication to non-DMP receivers.
CID - Contact ID communication to non-DMP receivers. This format sends the
report codes of the Ademco
®
Contact ID communication format.
3.3 ACCOUNT NUMBER
Enter the account number sent to the receiver.
DD - The range of account numbers for Digital Dialer is 1 to 65,535. For account
numbers of four digits or less, you do not have to enter leading zeros. The panel
automatically right justifies the account number.
4-2 - The range of account numbers using 4-2 communication is 1 to 9999.
CID - The range of account numbers using Contact ID communication is 1 to 9999.
3.4 TRANSMIT DELAY
Enter the length of time the panel waits before sending burglary alarm reports to
the receiver. The available range is 10 to 60 seconds in 10-second increments.
Alarm bells and relay outputs are not delayed during this period. Burglary Type
output must be programmed for Steady output.
If the area where the alarm occurred is disarmed during the Transmit Delay, only
an Abort Report is sent. Abort Reports must be set to YES.
Enter zero to disable Transmit Delay.
3.5 DTMF
YES enables tone dialing. NO enables rotary dialing.
3.6 DEFER RECALL TEST
Select YES to allow the programmed test report to be deferred if the panel
communicates with a receiver within the time set in Test Frequency. Select NO to
send the test report as programmed in Test Frequency, regardless of previous
panel communication.
3.7 TEST FREQUENCY
Allows you to set how often the panel's test report is sent to the receiver. Enter
from 1 to 60 days. Enter zero to disable the test report.
3.8 RECEIVER 1 PROGRAMMING
Allows you to set the reporting options for the first receiver the panel attempts to
contact when sending reports. The XR6/XR10 supports communication to two
receivers.
3.9 ALARM REPORTS
Select YES to enable Abort, Alarm, Alarm Restoral, Alarm Bell Silenced, Ambush,
Exit Error, and System Recently Armed reports to be sent to this receiver.
3.10 SUPERVISORY/TROUBLE REPORTS
Select YES to enable supervisory, trouble, trouble restoral, force armed, and zone
fault reports to be sent to this receiver.
ACCOUNT NO:12 3 45
XMIT DELAY: 0
DTMF NO YES
COMMUNICATION
COMM TYPE: NONE
NONE DD 4-2 CID
TEST FREQ: 0
DFR TEST NO YES
SPV/TRBL NO YES
ALARM NO YES
RECEIVER 1 PROG