•J3-13: Pwr Mod Fail. One or more power modules has a fault.
•J3-12: Low B+. See “Low B+ voltage” on page 9-2.
•J3-11: High VSWR. See “High VSWR shutback” on page 9-3.
•J3-17: Cutback. See “Cutback level (1-8)” on page 9-4.
•J3-16: Shutback. Indicates that a shutback is currently active.
•J3-3: RF On Status. Indicates that the RF On LED is active, showing the operator’s request
for RF power.
• J3-(5,6,7,8,9,10): Preset (1-6) Status. Indicates which preset is currently active.
•J3-4: Remote Status. Indicates whether or not the system is in Remote or Local control mode.
Changes can only be made remotely if the transmitter is set to Remote mode. The local