Installation manual

XR6/XR3 Installation Manual Connecting ac power
Issue 3.0 2009-07-15 Page 5-1
Section 5: Connecting ac power
To connect ac power to the transmitter, perform the following steps:
1. Run the ac power cable from the ac disconnect switch to the transmitter, passing all the
conductors, as a group, through a ferrite toroid (provided in the ancillary kit). The preferred
entry point is the top of the transmitter. Internal conduit is provided to guide the cable to the
power supply space at the bottom of the transmitter (see Figure 5.1).
Figure 5.1: Location of the ac power cable entry (top view of XR6/XR3 transmitter)
WARNING: Ensure that wiring sizes are appropriate. ac wiring must be
installed by a qualified, locally-certified electrician.
Front
Rear
AUDIO
CABLE
ENTRY
AC IN