Installation guide
Page 1
Introduction
2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282
XR6/XR10/XR20 Installation Guide
Panel Specifications
1.1 Power supply
Transformer Input: 16.5 VAC 40VA (Models 320 wire-in or 321 plug-in)
16.5 VAC 20VA (Model 324 plug-in)
Standby Battery: 12 VDC 7.0Ah (40VA transformer charges up to 2 batteries)
Auxiliary Output: 12 VDC at 500mA
Bell Output: 12 VDC at 1.5 Amps with 40VA transformer, 600mA with 20VA transformer
Smoke Detector Output: 12 VDC at 100mA
All circuits inherent power limited
1.2 Communication
Built-in SDLC Digital Dialer communication to DMP Model SCS-1 Receivers
Built-in 4-2 communication to non-DMP receivers
Built-in M2E (Radionics Modem IIe) communication to non-DMP receivers (XR20 only)
Built-in CID (Contact ID) communication to non-DMP receivers
Either panel can operate as a local system.
1.3 Panel zones
Nine 1k W EOL burglary zones (zones 1 to 9), (zones 1 to 5 on XR6)
One 3.3k W EOL Class B powered fire zone with reset capability (zone 10 on XR10 and XR20), (zone 6 on XR6)
1.4 Keypads
You can connect up to four of the following supervised keypads to the XR6/XR10/XR20 panels.
• 16 or 32 character alphanumeric keypads
• 10-zone LED keypads
In addition, the following zone expanders can be added to the XR20 panel:
• Four and single point zone expanders
• Single point PIR and glassbreak detectors
When using the FA426 Wireless Receiver, the XR20 allows unsupervised devices to be added to address five.
1.5 Outputs
The XR6/XR10/XR20 panels provide four open collector outputs rated for 50mA each. See section 12.1. A Model
300 Wire Harness is required. The open collector outputs provide the ground connection for a positive voltage
source.
1.6 Enclosure specifications
The XR6/XR10/XR20 panel ships in an enclosure with EOL resistors, battery leads, user's guide, and
programming sheet.
Size: 12.5" W x 9.5" H x 2.75" D
Weight: 4 lbs
Color: Gray or Black
Construction: 20 gauge cold rolled steel