Installation guide

Page 14
Installation
2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282
XR6/XR10/XR20 Installation Guide
UL 1023 SPECIFICATIONS
Household Burglar-Alarm System Units
16.1 Bell cutoff
The bell cutoff time cannot be less than five minutes. See section 7.2 of the XR6/XR10 Programming Guide
(LT-0230) and XR20 Programming Guide (LT-0305).
16.2 Entry delay
The maximum entry delay used must not be more than 45 seconds. See section 6.4 of the XR6/XR10
Programming Guide (LT-0230) and XR20 Programming Guide (LT-0305).
16.3 Exit delay
The maximum exit delay used must not be more than 60 seconds. See section 6.5 of the XR6/XR10
Programming Guide (LT-0230) and XR20 Programming Guide (LT-0305).
16.4 Zone expansion on 4-wire bus
When expansion zones are used, the keypad and zone expander 4-wire bus must be limited to three feet in
length unless an external communication fail indicator is added. A 12 VDC relay may be wired as a
communication fail indicator. To install, connect the negative side of the indicator to one of the panel's
annunciator outputs and the positive side to the smoke power (terminal 11 of the XR6/XR10/XR20 panel). See
section 7.5C of the XR6/XR10 Programming Guide (LT-0230) and XR20 Programming Guide (LT-0305).
In addition to the wiring described above, a 24 hour zone must be programmed to activate the appropriate
annunciator output.
UL 1610 and 1076 SPECIFICATIONS
Central-Station and Proprietary Burglar-Alarm Units
17.1 Opening/Closing reports
The Opening/Closing Reports option must be programmed as YES. See section 5.2 of the XR6/XR10
Programming Guide (LT-0230) and XR20 Programming Guide (LT-0305).
17.2 Automatic bell test
This option must be programmed as YES. See section 7.3 of the XR6/XR10 Programming Guide (LT-0230) and
XR20 Programming Guide (LT-0305).
17.3 Proprietary dialer
The Model XR6/XR10/XR20 provides Grade A proprietary service when configured as a digital dialer.