Specifications
XR5 Programming Guide Digital Monitoring Products
19
aPPendiX
10.4 Walk Test
The XR5FC and XR5SL panels provide a walk test feature that allows a single technician to test the
protection devices connected to zones on the system. To conduct the Walk Test:
From the 630F Keypad
1. From the keypad, enter the code 8144. If the system is monitored and the communication type is set
to DD, the system sends a System Test Begin report to the central station. The keypad then displays
WALK TEST for four seconds followed by TRIPS: X X X END. The " X X X " represents the number of
trips that occur during the Walk Test.
the panel sounds the alarm bells for two seconds and then performs an automatic Sensor Reset. -
Continue tripping devices until the entire system has been tested. The trip counter on the keypad
display increments by one each time a device is opened or shorted
3. To end the test, press the Select key under END. The panel sends a System Test End to the central
failed to trip. Below are two examples:
Keypad display: SOUTH SMOK –FAIL Keypad display: LOBBY HEAT –FAIL
From the 692F LED Keypad
1. From the keypad, enter the code 8144. If monitored, the system sends a System Test Begin report to
Continue tripping devices until the entire system has been tested.
sends a System Test End to the central station.
10.5 Table of Common Keypad Messages
Message Meaning Possible Solutions
The user code you entered is not recognized
by the system.
Check the user code and try again.
The system is not getting proper power.
Battery is either low or missing.
good.
or
There is a problem with one or more of the
components in the system.
wire to the keypad. You may also need to check that all of the
keypads and expansion modules on the bus are good.
The system is performing another task with a
higher priority.
Wait a few moments for the system to complete the task. If
the message displays for a long period of time, the processor
could be locked up.
The panel attempted to communicate with
the central station three times and has not
succeeded.
Verify your communication type, account number, and phone
properly.
(entering
Programming)
A lockout code is programmed into the panel.
The panel is dialing the Central Station to
indicate local programming session and out-
of-service status