Installation guide
Page 4
Introduction
2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282
XR3F/XR5F Installation Guide
3.3 XR5SL Wiring diagram
The XR5SL system below shows some of the accessory devices you can connect for use in various applications.
3.4 Lightning protection
Metal Oxide Varistors and Transient Voltage Suppressors on the panel help protect against voltage surges on
input and output circuits of the XR5 panels. Additional surge protection is available by installing the DMP 370 or
370RJ Lightning Suppressors.
3.5 Security Command
®
keypads
You can connect the Models 670, 690, 692F, 770, 771, or 790 Security Command keypads to the 4-wire keypad
data bus provided by the panel on terminals 7, 8, 9, and 10.
Figure 2: XR5SL wiring diagram
Panel Reset
Zones 2 to 5 compatibility identifier: A
Maximum operating range:
8.8 VDC to 14.2 VDC.
RED
BLACK
22 GA. MIN
GREEN
22 GA. MIN
BLACK
22 GA. MIN
YELLOW
22 GA. MIN
RED
Maximum AC wire distance
With 16 gauge wire: 70 feet
With 18 guage wire: 40 feet
Cold Water Pipe
Earth Ground
16 to 18 gauge wire
Output Header J11
Two Form C (SPDT) Outputs.
ZONE 2
AC
1
234
78
10 11 12
13
14
15
16
AC B+ B–
9
RED
YEL GRN
BLK
Z1B–
Z2 –
Z2+
3.3k Ω
Heat detectors, pull stations, or any other contact devices
listed for Fire Protective Signaling can be connected to
zones 1 to 5.
1
2
3
4
J12
Z1A–
Z1B+
Z1A+
MODEL XR5
MAIN
BACKUP
PANEL
RESET
J11
N/C COM N/O N/C COM N/O
Output Header J12
Four Open Collector Outputs.
Use Model 300 Harness.
50mA at 30 VDC resistive
Relay Sockets for Optional
Form C Outputs on J11
J4
J5
Telephone Connections
ZONE 1
J10 Trouble Annunciator Header
M
M
DMP transformer
Model 320
16.5 VAC 40VA
wire-in
Model 690
100mA at 8 to 16 VDC.
Direct connect to unswitched
120 VAC 60 Hz
Secondary Power Supply
1.2 Amps max. charging current.
Use only 12 VDC rechargable
batteries. DMP Model 367.
Replace every 3 to 5 years.
All outputs must be
connected to devices
located within the same
room as the panel.
Up to 500mA auxiliary
current at 12 VDC from
Terminal 7.
See section 11.4 in the XR5SL
Installation Guide (LT-0299) for a list
of approved 2-wire smoke detectors.
377 Trouble Annunciator Module
Refer to the Model 377 Installation
Instructions (LT-0314).
16-Character Keypads
32-Character Keypads
10-Zone LED Keypads
3.3k Ω
ZONE 5
Model 692F
40mA at 8 to 16 VDC.
Model 670
100mA at 8 to 16 VDC
(125mA with display lit).
For sprinkler
supervision,
Normally Open
devices must be
used.
Output 1
Output 2
OUTPUT 1
OUTPUT 2
SILENCE/RESET
PUSH FOR ONE SECOND
Silence/Reset
Button
Silence/Reset
Header
17
18
Z3 –
Z3+
19
20
Z4 –
Z4+
21
22
Z5 –
Z5+
W
W
LED Keypads and up to two
alpha keypads can be
connected to the XR5SL.
ZONE 3
3.3k Ω
S
S
ZONE 4
3.3k Ω
H
M
Keypads
S S
S
S
S
S S
S
S
S
S
S S
S
S S
= Supervised Circuit
S
Wiring on
terminals 5
through 22 must
exit to the right
and maintain a
1/4" separation
from the AC and
battery positive
wiring.