Programming instructions

XR500 Series Programming Guide Digital Monitoring Products
47
zone informaTion
19.9
NEXT ZN? NO YES
Next Zone
Select YES to terminate zone programming. The display returns to Zone Number,
allowingyoutoenteranewzonenumber.SelectNOtomakealterationstothe
AlarmActionforazone.AlarmActionisdenedbeginningwithsection16.12.
Toprogramzonesforwirelessoperation,selectNOattheNEXTZONE-NOYES
option.TheWIRELESSNOYESoptiondisplays.Ifthezoneyouareprogramming
isintendedforwirelessdevices,selectYES.SelectNOtocontinueprogramming
non-wirelesszonesinthe500to999range.
• Zones400to449canbeprogrammedfor1100SeriesKeyFobs.
• Zones500to699canbeprogrammedforFASeriesWireless.
• Zones500through999canbeprogrammedforDMP1100SeriesWireless.
DMP Wireless
For a DMP 1100X Wireless Receiver set the House Code from 1 to 50. See House Code programming in
SystemOptions.Zones500through999canbeprogrammedasWirelesszones.SettheXR500Seriespanel
J23jumpertoXtoenableon-boardDMPWirelessoperation.BrieyresetthepanelusingtheJ16jumper
toactivateWirelessoperation.RefertotheXR500SeriesInstallationGuide(LT-0681).
For an 1100 Series Key Fob see section 19.11.
For an FA Series Remote Wireless Receiver see section 19.12.
NOTE: AllwirelessprogrammingisstoredintheXR500Seriespanel.The1100XWirelessReceiverobtains
the necessary programming information from the panel each time the receiver powers up, when the
programmerSTOProutineisselectedorthepanelisreset.Thereceivermemoryrefreshtakesupto10
secondstocompletedependingonthenumberofwirelesszonesprogrammedandtheRedLEDremainson
during this time. Normal receiver operation is inhibited during the memory refresh period.
19.10 Wireless
Select YES to program this zone as a DMP wireless zone. You must program
the wireless House Code prior to adding DMP wireless zones to the system. See
HouseCodeprogramminginSystemOptions.DefaultisNO.
19.10.1
TRANSMITTER
SERIAL#: XXXXXXXX
Serial Number Entry
Entertheeight-digitserialnumberfoundonthewirelessdevice.
ALREADY IN USE
ZONE NUMBER: XXX
This message displays when the serial number is already programmed for
another zone. The programmed zone number displays.
19.10.2
TRANSMITTER
CONTACT:XXXXXXXX
Contact
Thisoptiondisplaysiftheserialnumberenteredisforan1101or1103Universal
Transmitteror1114WirelessFour-ZoneExpander.Pressanytoprowkeyto
select the contact.
TRANSMTR CONTACT
INT EXT
Thisoptiondisplayswhenprogrammingan1101or1103Transmitter.SelectINT
to use the internal reed switch contacts. Select EXT to connect an external
devicetothe1101or1103terminalblock.DefaultisINTERNAL.
ByallowingbothoftheModel1101or1103transmittercontacts(INTand
EXT)tobeusedatthesametime,twozonesmaybeprogrammedfrom
onetransmitter.Whenusingbothcontacts,youmustuseconsecutivezone
numbers.Zones531and532orzones890and891areacceptablezone
assignments.
Forexample,programtransmitterserialnumber01345678asZone521with
an INT contact type and Zone 522 with an EXT contact type. The same serial
number is used for both zones.
Note:Whenusingthe1103UniversalTransmitterinaULlistedCommercial
Burglary installation, the external contact cannot be used.
ZONE INFORMATION
WIRELESS? NO YES