Programming instructions
XR500 Series Programming Guide Digital Monitoring Products
47
zone informaTion
19.9
NEXT ZN? NO YES
Next Zone
Select YES to terminate zone programming. The display returns to Zone Number,
allowingyoutoenteranewzonenumber.SelectNOtomakealterationstothe
AlarmActionforazone.AlarmActionisdenedbeginningwithsection16.12.
Toprogramzonesforwirelessoperation,selectNOattheNEXTZONE-NOYES
option.TheWIRELESSNOYESoptiondisplays.Ifthezoneyouareprogramming
isintendedforwirelessdevices,selectYES.SelectNOtocontinueprogramming
non-wirelesszonesinthe500to999range.
• Zones400to449canbeprogrammedfor1100SeriesKeyFobs.
• Zones500to699canbeprogrammedforFASeriesWireless.
• Zones500through999canbeprogrammedforDMP1100SeriesWireless.
DMP Wireless
For a DMP 1100X Wireless Receiver set the House Code from 1 to 50. See House Code programming in
SystemOptions.Zones500through999canbeprogrammedasWirelesszones.SettheXR500Seriespanel
J23jumpertoXtoenableon-boardDMPWirelessoperation.BrieyresetthepanelusingtheJ16jumper
toactivateWirelessoperation.RefertotheXR500SeriesInstallationGuide(LT-0681).
For an 1100 Series Key Fob see section 19.11.
For an FA Series Remote Wireless Receiver see section 19.12.
NOTE: AllwirelessprogrammingisstoredintheXR500Seriespanel.The1100XWirelessReceiverobtains
the necessary programming information from the panel each time the receiver powers up, when the
programmerSTOProutineisselectedorthepanelisreset.Thereceivermemoryrefreshtakesupto10
secondstocompletedependingonthenumberofwirelesszonesprogrammedandtheRedLEDremainson
during this time. Normal receiver operation is inhibited during the memory refresh period.
19.10 Wireless
Select YES to program this zone as a DMP wireless zone. You must program
the wireless House Code prior to adding DMP wireless zones to the system. See
HouseCodeprogramminginSystemOptions.DefaultisNO.
19.10.1
TRANSMITTER
SERIAL#: XXXXXXXX
Serial Number Entry
Entertheeight-digitserialnumberfoundonthewirelessdevice.
ALREADY IN USE
ZONE NUMBER: XXX
This message displays when the serial number is already programmed for
another zone. The programmed zone number displays.
19.10.2
TRANSMITTER
CONTACT:XXXXXXXX
Contact
Thisoptiondisplaysiftheserialnumberenteredisforan1101or1103Universal
Transmitteror1114WirelessFour-ZoneExpander.Pressanytoprowkeyto
select the contact.
TRANSMTR CONTACT
INT EXT
Thisoptiondisplayswhenprogrammingan1101or1103Transmitter.SelectINT
to use the internal reed switch contacts. Select EXT to connect an external
devicetothe1101or1103terminalblock.DefaultisINTERNAL.
ByallowingbothoftheModel1101or1103transmittercontacts(INTand
EXT)tobeusedatthesametime,twozonesmaybeprogrammedfrom
onetransmitter.Whenusingbothcontacts,youmustuseconsecutivezone
numbers.Zones531and532orzones890and891areacceptablezone
assignments.
Forexample,programtransmitterserialnumber01345678asZone521with
an INT contact type and Zone 522 with an EXT contact type. The same serial
number is used for both zones.
Note:Whenusingthe1103UniversalTransmitterinaULlistedCommercial
Burglary installation, the external contact cannot be used.
ZONE INFORMATION
WIRELESS? NO YES