Programming instructions

Digital Monitoring Products XR500 Series Programming Guide
38
PC log rePorTS
PC Log Reports
17.1
PC LOG REPORTS
PC Log Reports
ThissectionallowsyoutoprogramthetypesofPCLogReportsthepanelsends
through the 462N Network Interface Card or through the J21 Serial Connector
directly on the XR500 Series panel. The reports include information such as the type
of activity, time and date of the activity, and user name and number. These data
reports can be accessed from a PC using the Advanced Reporting Module. See the
InstallationGuide(LT-0681)fordetailedJ21setupinformationortheUser’sGuide
(LT-0683)formoreinformation.
Note:ThenetworkconnectionthatsendsPCLogReportsisnotmonitoredfor
networktrouble.ThePCLogReportsoptionshouldNOTreplacetheprimary
communication method or act as a backup communication method.
If there is trouble with the network connection, the panel continues to attempt to
sendthePCLogReportsuntiltheconnectionisreestablished.Thepanelthensends
the reports. A Network Trouble message is NOT sent if the connection is lost since
thisreporttoolisnotdesignedtobemonitoredbyareceiver.ThePCLogReports
have the lowest priority of panel reports sent.
Forinformationaboutthe462NcardcapabilitieswithPCLogReportsandNetwork
Communication method, see 462N Card Examples in the Appendix.
Note:ThePCLogAddressStringenteredCANNOTbethesameasthatenteredin
Communication.
17.2
COMM TYPE: NONE
Communication Type
NONE NET 232
SelecttheCommunicationTypetosendthePCLogReports.DefaultisNONE.
17.3
NET IP ADDRESS
Net IP Address
ThisoptiondisplayswhentheCommunicationTypeforPCLogReportsisNET.Enter
the IP address containing up to 16 characters. The Net IP Address must be unique and
cannot be duplicated on the network. Enter all 12 digits and leave out the periods.
Forexample,enterIPaddress192.168.0.250as192168000250.Theperiodsdisplay
automatically.
17.4
NET PORT 2001
Net Port
ThisoptiondisplayswhenCommunicationTypeforPCLogReportsisNet.Enterthe
Portnumber.Validnumbersarefrom0to65535.Defaultis2001.
17.5
232 COMM PORT: O
232 Communication Port
ThisoptiondisplayswhenCommunicationTypeforPCLogReportsis232.Toenable
PCLogReports,selecteithertheon-boardconnector(O)orselectA,B,C,DorEfor
the corresponding slot in use on the DMP Model 462N Network Interface card. The
slotsarelabeledfromlefttoright,beginningwithA.DefaultisO.
SettheXR500SeriespanelJ23jumpertoRandbrieyresetthepanelusingtheJ16
jumpertoactivateRS-232operation.
17.6
232 SETUP:
232 Setup
ThisoptiondisplayswhenCommunicationTypeforPCLogReportsis232.Enterup
to32characters.
17.7
ARM/DIS NO YES
Arm and Disarm Reports
Sendsarming,disarmingandLatetoCloseevents.Includestheareanumber,name
and action, the user number and name, and the time and date.
17.8
ZONE NO YES
Zone Reports
Sends changes in the status of active zones. Includes the zone number, name, type,
theaction(alarm,trouble,bypass,etc.),usernumber(ifapplicable),andarea
name.ForaWalkTest,VerifyandFailmessagesaresentforeachzone.
17.9
USR CMDS NO YES
User Command Reports
Sends user code changes, schedule changes, and door access denied events.