Programming instructions
XR500 Series Programming Guide Digital Monitoring Products
19
remoTe oPTionS
Remote Options
7.1
REMOTE OPTIONS
Remote Options
ThissectionallowsyoutoentertheinformationneededforRemoteCommand/
Remote Programming operation.
7.2
RMT KEY:
Remote Key
This option allows you to enter a code of up to eight digits for use in verifying
theauthorityofanalarmorservicereceivertoperformaremotecommand/
programmingsession.TheRemoteLink™programmustgivethecorrectkeytothe
panel before being allowed any remote functions. All panels are shipped from the
factory with the key preset as blank.
To enter a remote key or change the current one, press a top row Select key and
enteranycombinationofuptoeightdigits.PressCOMMAND.Thecurrentkeynever
displays.
7.3
MFG AUTH NO YES
Manufacturer Authorization
Select YES to allow DMP Technical Support technicians to access the panel during
system service or troubleshooting. This authorization automatically expires within
one hour.
DMP remote service is provided on a read only basis: DMP technicians can look
at the system programming and make suggestions only. Alterations can only be
accomplished by installing company service personnel.
7.4
ARM RINGS: 8
Armed Rings
Enter the number of rings the panel counts before answering the phone line when
allsystemareasarearmed.Anynumberfrom1to15canbeentered.If0(zero)
is entered, the panel does not answer the phone when all system areas are armed.
ThedefaultArmedRingsis8(eight).
Answering machine bypass procedure:Enteringanumbergreaterthan0(zero)into
either Armed Rings or Disarmed Rings, allows a central station operator to connect
remotely with the panel.
How it works: The operator calls the panel, allows the telephone to ring one time,
and then hangs up. The panel stores this as an attempt to communicate. The
operatorthencallsbackwithin30seconds.Thepanelseizesthetelephonelineto
allow remote programming.
Note: This feature does not interfere with the normal operation of the Arm Rings or
Disarm Rings functions.
7.5
DISARM RINGS: 8
Disarmed Rings
Enter the number of rings the panel counts before answering the phone line while
anysystemareasaredisarmed.Anynumberfrom1to15canbeentered.If0(zero)
is entered, the panel does not answer the phone when any system area is disarmed.
ThedefaultnumberofDisarmedRingsis8(eight).
7.6
ALR RCVR NO YES
Alarm Receiver Authorization
Select YES to enable remote commands and programming to be accepted from the
alarmSCS-1RReceiver.TheRemoteKeyoptioncanalsoberequired.
WithYESselected,thepanelrequeststhereceiverkeyduringitsrstcommunication
withtherstSCS-1RReceiver.Thepanelretainsthisalarmreceiverkeyinmemory
and allows remote commands to be accepted from the alarm receiver. If an alarm
occurs during a remote connect, the alarm report is immediately sent to this
receiver only.
WhenNOisselected,remotecommandsandprogrammingarenotacceptedfrom
thealarmSCS-1RReceiver.