Installation guide

Digital Monitoring Products XR2500F Installation Guide
34
COMPLIANCE
XR2500F Installation Guide Digital Monitoring Products
35
COMPLIANCE
UL 1610 AND 1076 Specications
Central-Station and Proprietary Burglar-Alarm Units
32.1 Opening/Closing Reports
The Opening/Closing Reports option must be programmed as YES. See the XR500 Series Programming Guide
(LT-0679).
32.2 Closing Wait
The Closing Wait option must be programmed YES. See the XR500 Series Programming Guide (LT-0679).
32.3 Entry Delay
The maximum entry delay used must not be more than 60 seconds. See the XR500 Series Programming Guide
(LT-0679).
32.4 Exit Delay
The maximum exit delay used must not be more than 60 seconds. See the XR500 Series Programming Guide
(LT-0679).
32.5 Proprietary Dialer
The Model XR2500F provides Grade A proprietary service when congured as a digital dialer.
32.6 Grade B Central Station
Grade B Central Station service can be provided under by adding a Grade A Ademco AB12M bell and bell
housing.
32.7 Bell Cutoff
The Bell Cutoff time cannot be less than 15 minutes. See the XR500 Series Programming Guide (LT-0679).
32.8 AA Network Communication
High Line Security is provided when congured as a NET system using an XR500N panel or an XR500 panel
with an iCOM™ Internet Alarm Router. The NET Check-in time must be set from 01 to 06 minutes or AA.
When a dialer is required for 06 minute check-in time, an attack resistant enclosure (DMP Model 350A) is
required. When the check-in time is set to a number less than 200 seconds, an attack resistant enclosure is
not required. See sections 3.2, 3.2.1, and 3.3 of the XR500 Series Programming Guide (LT-0679).
To provide High Line Encrypted security, install an XR500E panel or an XR500 panel with an iCOM-E™
Encrypted Network Alarm Router.
For high line security operation, communication between the Premise and Supervising Station provides 128
bit encryption when using an XR500E panel or an XR500 panel with an iCOM-E Encrypted Network Alarm
Router.
The Model XR500 Series Protected Premises Control Unit is suitable for Grade AA service when congured for
NET communication with SCS-1/SCS-1R receiving system. This conguration is approved for the following:
AMCX - Central Station Alarm Units