User`s guide

Output Schedules
Output Schedules
menu is available on:
1812
1912
1912XR
XR40
XR200
XR200-485 Classic
XR200-485 Enhanced
XR200-485B Enhanced
XR2400F
XR500
XR500N
XR500E
XR2500F
XR100
XR100N
Output Schedules allows you to set the times when relay outputs connected to your system
turn on and off automatically.
Identifier
Output:
Enter the output number that you wish to assign a schedule.
To program door schedules, enter D and a device address number.
XR500 Series or XR2500F — select D01 to D16
XR100 Series — select D01 to D8
Note: Door schedules are available on the XR500 Series, XR2500F, and XR100 Series. All
other panels program output schedules using output numbers only.
Schedule:
Enter the schedule number that you want to program. The Schedule field
allows you to set up to 100 different scheduled times for relay outputs and door access
relays connected to your system to turn on and off automatically. The maximum number
of schedules you may assign per door access relay or relay output is 8.
On
: Enter the time that you want to turn on the output. Repeat for each day of the week
that you wish to program.
Off
: Enter the time that you want to turn off the output. Repeat for each day of the week
that you wish to program.
System Link User’s Guide
56