Installation guide
Digital Monitoring Products XR500 Series Installation Guide
28
ComPlIanCe
26.2 Entry Delay
The maximum entry delay used must not be more than 60 seconds when using Model 350A Attack housing. See the
XR500SeriesProgramingGuide(LT-0679).
26.3 Exit Delay
Themaximumexitdelayusedmustnotbemorethan60seconds.SeetheXR500SeriesProgrammingGuide
(LT-0679).
26.4 Bell
A local audible signal appliance must be used such as Ademco AB12M bell and bell housing.
26.5 Bell Cutoff
TheBellCutofftimecannotbelessthan15minutes.SeetheXR500SeriesProgrammingGuide(LT-0679).
26.6 Automatic Bell Test
TheAutomaticBellTestoptionmustbeprogrammedasYES.SeetheXR500SeriesProgrammingGuide(LT-0679).
26.7 Line Security for Police Connect
BasiclinesecurityisprovidedwhentheModelXR500Seriesisconguredasadialersystem.
26.8 Standard or Encrypted Line Security
StandardLineSecurityisprovidedwhenconguredasaPath1NETsystemusinganXR500NpaneloranXR500panel
with an iCOM™ Network Alarm Router. The NET Check-in time must be set to 06 minutes or RDM. When programmed
for Standard Line Security, Exit Time Restart is disabled. When a dialer is required for 06 minute check-in time,
an attack resistant enclosure (DMP Model 350A) is required. When the check-in time is set to a number less than
200 seconds, an attack resistant enclosure is not required. See sections 3.2, 3.2.1, and 3.3 of the XR500 Series
ProgrammingGuide(LT-0679).
To provide Encrypted Line security, install an XR500E panel or an XR500 panel with an iCOM-E™ Encrypted Network
Alarm Router.
ForEncryptedLinesecurityoperation,communicationbetweenthePremiseandSupervisingStationprovides128bit
encryption when using an XR500E panel or an XR500 panel with an iCOM-E Encrypted Network Alarm Router.
26.9 Wireless Audible Annunciation Option
The Wireless Audible option must be selected as ANY for commercial applications.
26.10 Model 463G CELL Only, Standard or Encrypted Line Security
Standard or Encrypted Line Security is provided when programmed using CELL with no backup. XR500 cellular
communication is used as primary with a 3 minute check-in when armed or disarmed.
Path 1 programming
Comm Type: = CELL Checkin: = 3 minute
Path Type: = Primary FailTime:=3minute
Encrypt: = NO or YES* Test Rpt: = NO
Sub Code: = NO or YES
*ForEncryptedLineSecurity,programaPassphraseinNetworkOptions.
26.11 Model 463G CELL with Dialer Backup, Standard or Encrypted Line Security
Standard or Encrypted Line Security is provided when programmed using CELL with DD (digital dialer) as a backup.
XR500 cellular communication is used as primary with a 6 minute check-in when armed, and a random check-in over
a 60 minute period when disarmed. The digital dialer sends a daily test signal and is backup.
Path 1 programming Path 2 programming
Comm Type: = CELL Comm Type: = DD
Path Type: = Primary Path Type: = Backup (operates as second method)
Test Rpt: = NO Test Rpt: = YES
Checkin: = 6 minute, or RND (random) TestFreq:=Daily
FailTime:=6minute,orRND(random) Duplicate Alarms: = YES
Encrypt: = NO or YES*
Sub Code: = YES