Installation guide
XR500 Series Installation Guide Digital Monitoring Products
23
ComPlIanCe
Universal Burglary Specications
20.1 Introduction
Theprogrammingandinstallationspecicationscontainedinthissectionmustbecompletedwheninstallingthe
XR500Seriespanelinaccordancewithanyoftheburglarystandards.Additionalspecicationsmayberequiredbya
particular standard.
20.2 Wiring
AllwiringmustbeinaccordancewithNEC,ANSI/NFPA70,ANSI/UL681,andANSI/UL827forallburglary
installations. All transformer wires must be installed in conduit.
20.3 Control Outside of Protected Area
A Potter EVD or Sentrol 5402 should be used in place of a lined cabinet when the panel is installed outside of the
protectedarea.Frontandreartamperswitchesarerequired.Refertothesystemwiringdiagram.
20.4 Police Station Phone Numbers
The digital dialer telephone number programmed for communication must not be a police station phone number.
20.5 Bypass Reports
The Bypass Reports option must be programmed as YES for all listed burglary applications. See the XR500 Series
ProgrammingGuide(LT-0679).
20.6 System Maintenance
To ensure continuous satisfactory operation of any alarm system, proper installation and regular maintenance by the
installing alarm company and frequent testing by the end user is essential. Offering a maintenance program and
acquainting the user with the correct procedures for system use and testing is also the responsibility of the installing
alarm company.
20.7 Listed Receivers
OperationhasbeenveriedwiththeDMPSCS-1R,Sur-GardSG-HLR2-DG,FBIICP220PB,Osborne-HoffmanQuick-
Alert, and Radionics D6500 receivers. It is the installer’s responsibility to verify compatibility between the XR500
Series and the receiver used during installation. The installer shall verify the compatibility of the receiver and the
system on a yearly basis.
20.8 Power Supply Supervision
Forcommercialburglaryapplicationsthepowersupplyforalllocalbellsshallbeunder24-hourprotection.Referto
section 6 in this document.
20.9 Wireless Tamper
The Zone Information Disarmed Open Message to Transmit must be programmed Trouble (T). See the XR500 Series
ProgrammingGuide(LT-0679).(NotapplicabletoANSI/UL1023).
20.10 Wireless External Contact
When used, the External Contact of 1101 or 1102 must be programmed Normally Closed. See the XR500 Series
ProgrammingGuide(LT-0679).
20.11 Wireless Supervision Time
TheZoneInformationSupervisionTimecannotbesetto0(zero).SeetheXR500SeriesProgrammingGuide
(LT-0679).
20.12 Detect Wireless Jamming
TheDetectWirelessJammingoptionmustbeprogrammedYES.SeetheXR500SeriesProgrammingGuide(LT-0679).
(Not applicable to ANSI/UL 1023).