Installation guide

XR500 Series Installation Guide Digital Monitoring Products
23
ComPlIanCe
Universal Burglary Specications
20.1 Introduction
Theprogrammingandinstallationspecicationscontainedinthissectionmustbecompletedwheninstallingthe
XR500Seriespanelinaccordancewithanyoftheburglarystandards.Additionalspecicationsmayberequiredbya
particular standard.
20.2 Wiring
AllwiringmustbeinaccordancewithNEC,ANSI/NFPA70,ANSI/UL681,andANSI/UL827forallburglary
installations. All transformer wires must be installed in conduit.
20.3 Control Outside of Protected Area
A Potter EVD or Sentrol 5402 should be used in place of a lined cabinet when the panel is installed outside of the
protectedarea.Frontandreartamperswitchesarerequired.Refertothesystemwiringdiagram.
20.4 Police Station Phone Numbers
The digital dialer telephone number programmed for communication must not be a police station phone number.
20.5 Bypass Reports
The Bypass Reports option must be programmed as YES for all listed burglary applications. See the XR500 Series
ProgrammingGuide(LT-0679).
20.6 System Maintenance
To ensure continuous satisfactory operation of any alarm system, proper installation and regular maintenance by the
installing alarm company and frequent testing by the end user is essential. Offering a maintenance program and
acquainting the user with the correct procedures for system use and testing is also the responsibility of the installing
alarm company.
20.7 Listed Receivers
OperationhasbeenveriedwiththeDMPSCS-1R,Sur-GardSG-HLR2-DG,FBIICP220PB,Osborne-HoffmanQuick-
Alert, and Radionics D6500 receivers. It is the installer’s responsibility to verify compatibility between the XR500
Series and the receiver used during installation. The installer shall verify the compatibility of the receiver and the
system on a yearly basis.
20.8 Power Supply Supervision
Forcommercialburglaryapplicationsthepowersupplyforalllocalbellsshallbeunder24-hourprotection.Referto
section 6 in this document.
20.9 Wireless Tamper
The Zone Information Disarmed Open Message to Transmit must be programmed Trouble (T). See the XR500 Series
ProgrammingGuide(LT-0679).(NotapplicabletoANSI/UL1023).
20.10 Wireless External Contact
When used, the External Contact of 1101 or 1102 must be programmed Normally Closed. See the XR500 Series
ProgrammingGuide(LT-0679).
20.11 Wireless Supervision Time
TheZoneInformationSupervisionTimecannotbesetto0(zero).SeetheXR500SeriesProgrammingGuide
(LT-0679).
20.12 Detect Wireless Jamming
TheDetectWirelessJammingoptionmustbeprogrammedYES.SeetheXR500SeriesProgrammingGuide(LT-0679).
(Not applicable to ANSI/UL 1023).