Installation guide
Digital Monitoring Products XT30/XT50 Installation Guide
16
ComPlIanCe
Listed Compliance Specications
20.1 Introduction
Theprogrammingandinstallationspecicationscontainedinthissectionmustbecompletedwheninstalling
theXT30/XT50inaccordancewithanyoftheANSI/ULburglarystandards.Additionalspecicationsmaybe
required by a particular standard.
20.2 Bypass Reports
ThebypassreportsmustbeprogrammedasYESforalllistedburglaryapplications.
20.3 Current Draw
Thetotalcurrentdrawfromacombinationofauxiliary,smoke,andbelloutputterminalsmustnotexceed
1.6 Amps.
20.4 Battery Standby
For24Hourbatterystandbyoperation,use9.0Ahbatteries.
20.5 Auxiliary and Bell Current
ForULlistedapplications,themaximumauxiliarycurrentis400mA,andthemaximumbellcurrentis500mA.
20.6 Cross Zoning
Eachzonemusthavethecapabilityofprotectingthecommonareaindividually.
20.7 Software Version
ForULlistedapplications,theminimumsoftwareversionmustbeVersion103.
Household Burglar-Alarm System Units
ANSI/UL 1023
21.1 Bell Cutoff
The bell cutoff time cannot be less than four minutes.
21.2 Entry Delay
Themaximumentrydelayusedmustnotbemorethan45seconds.
21.3 Exit Delay
The maximum exit delay used must not be more than 60 seconds.
21.4 Wireless External Contact
Whenused,theExternalContactof1101,1102or1105mustbeprogrammedNormallyClosed.
21.5 Wireless Supervision Time
TheZoneInformationSupervisionTimecannotbesetto0(zero).
21.6 Wireless Audible Annunciation
TheWirelessAudibleoptionmustbeselectedasDAYforresidentialapplications.
21.7 Panel location
Mountpanelinsideprotectedarea.
21.8 Test Frequency
TheTestFrequencyoptionmustbeprogrammedtosendareportatleastonceevery30days.
Digital Burglar Alarm Communicator System Units
ANSI/UL 1635
22.1 Entry Delay
The maximum entry delay used must not be more than 60 seconds.
22.2 Exit Delay
The maximum exit delay used must not be more than 60 seconds.
22.3 Test Frequency
TheTestFrequencyoptionmustbeprogrammedtosendareportonceevery24hours.