ComPlIanCe
False Alarm Reduction Programmable Options (continued)
35.2 Call Waiting (ANSI/SIA CP-01-2000)
The Call Waiting default setting is disabled. To cancel the Call Waiting feature, program * (star) 7 0 P (pause), the
standardtelephonecodeprexthatcancelscallwaiting,intothetelephonenumberstring.CancelCallWaitingfor
telephonelinesthathaveCallWaitingoperationalonthetelephoneline.SeetheXR500SeriesProgrammingGuide
(LT-0679).
Caution: A call waiting cancel programmed on a non-call waiting telephone line, would prevent
communication to the central station.
35.3 Occupied Premise (ANSI/SIA CP-01-2000)
When only two areas are used, and area one is named Perimeter, and area two is named Interior, and no exit type
zone transition occurs during the exit delay because the premise continues to be occupied, the Interior area will
automatically disarm at the end of the exit delay.
35.4 Entry Delay (ANSI/SIA CP-01-2000)
OnlyuseEntryDelay1.DonotuseEntryDelay2,3,or4.SeetheXR500SeriesProgrammingGuide(LT-0679).
35.5 Minimum Installation Requirements (ANSI/SIA CP-01-2000)
SIA CP-01-2000 minimum system installation requirements include an XR500, a listed local Bell, and off premise
DACT communication to an SCS-1R receiver plus one of the following compatible keypads.
630FFireCommand™Center
690, 790, 639/793 Security Command™ keypads
7060, 7063, 7070, or 7073 Thinline™ keypads
7060A, 7063A, 7070A, or 7073A Aqualite™ keypads
7160, 7163, 7170, or 7173 Thinline™ keypads
7760 Clear Touch™ keypad
ULC S304 Specications
Signal Receiving Center and Premise Burglar Alarm Control Units
36.1 Level V Communication
LevelVcommunicationchannelsecurityisprovidedforInternet,Intranet,LANorWANnetworkswhenconguredas
a NET communicating system using the XR500N. Additionally, the following options must be programmed in XR500
Series panel Communication:
SUB CODE: YES
CHECKIN TIME: 2 MINUTES
FAILTIME: 3MINUTES
SEND COMM TRBL: YES
TCP COMM: YES
In addition, the SCS-101 Network Line Card installed in the SCS-1R Receiver must have the ACK Substitution Message
programmed as NO.