Installation guide

Digital Monitoring Products XR500 Series Installation Guide
30
ComPlIanCe
28.4 Mercantile Safe and Vault
When the DMP Model 350A or 350H Attack housing is used, the XR500 Series provides operation as a mercantile safe
and vault alarm. Bell Supervision and wiring must be in accordance with ANSI/UL 681. When the XR500 Series is
mounted outside the safe or vault, tamper protection and the Sentrol Model 5402 or Potter EVD listed vibration
detectors should be used.
28.5 Bell
A local audible signal appliance must be used such as Ademco AB12M bell and bell housing.
In a mercantile burglar alarm system, a mercantile alarm sounding device located within a building but outside the
protected area, is acceptable, provided it is rated for outside service and alarm conditions are transmitted to:
a) The dispatch location of the law enforcement agency having jurisdiction over the protected property or
b) A central station or residential monitoring station complying with the Standard for Central Station Alarm Services,
UL 827.
In a mercantile burglar alarm system, an alarm sounding device located within the area of greatest protection, or
outside the area of greatest protection but within an area protected by an alarm system and that shares a common
control unit with the system installed in the area of greatest protection, is acceptable provided it is rated for inside
service and alarm conditions are transmitted to:
a) The dispatch location of the law enforcement agency having jurisdiction over the protected property or
b) A central station or residential monitoring station complying with the Standard for Central Station Alarm Services,
UL 827.
Aninsidesoundingdeviceshallbemountedatleast10feet(3.05m)abovetheoororatthesurfaceoftheceiling.
Whenthereisxedconstructionwithintheareathatcouldprovideaccessforanintruder,thealarmsounding
deviceshallalsobemountedatleast4feet(1.2m),asmeasuredhorizontally,awayfromtheedgesofthexed
construction or at least 10 feet (3.05 m) above it so as to minimize access by an intruder.
28.6 Bank Safe and Vault (XR500N/XR500E only)
The Bank Safe and Vault option must be programmed as YES. The 72 hour battery standby must be provided. A
Rothenbuhler Model 5110 High Security Bell must be used.
28.7 Wireless Audible Annunciation Option
The Wireless Audible option must be selected as ANY for commercial applications.
Access Control System Units
ANSI/UL 294
29.1 Panel Designation
The XR500 Series panels are designated stand alone units.
29.2 Tamper Protection
ForlistedAccessControlinstallations,atamperswitchmustbeused.
29.3 Compatible Devices
The following devices are compatible with the XR500 Series panels.
Access Control
733 Wiegand Interface Module Proximity reader connector
734 Wiegand Interface Module Proximity reader connector
OP-08CB Motion Detector Infrared sensor
* PB-2 REX Button Exit control push button
PP-6005B Proxpoint Plus® Reader Proximity reader
MP-5365 Miniprox® Reader Slimline proximity reader
PR-5455 ProxPro® II Reader Long range reader with sounder
MX-5375 Maxi-Prox™ Reader Long range reader compatible with 1351 Prox Pass
* This device has not been investigated and shall not be used in listed installations.