Installation guide
Digital Monitoring Products XR500 Series Installation Guide
28
ComPlIanCe
27.4 Bell
A local audible signal appliance must be used such as Ademco AB12M bell and bell housing.
The alarm housing for a mercantile alarm system without a remote alarm transmission connection shall be mounted
on the outside of the building, visible from a public street or highway. It shall be accessible for examination and
repair. It shall also be located not more than four stories above the street level unless:
a) A second alarm sounding device and housing, intended for outside service, is mounted adjacent to the premises or
area of the building in which the alarm system is installed or
b) A second alarm sounding device, intended for inside service, is mounted within the premises.
Ineithercase,theoutsidealarmsoundingdeviceandhousingmaybemountedashighastheseventhoor.
27.5 Bell Cutoff
The Bell Cutoff time cannot be less than 15 minutes.
27.6 Automatic Bell Test
The Automatic Bell Test option must be programmed as YES.
27.7 Standard or Encrypted Line Security
StandardLineSecurityisprovidedwhenconguredasaPath1NETsystemusinganXR500NpaneloranXR500panel
with an iCOM™ Network Alarm Router. The NET Check-in time must be set to 06 minutes or RND When programmed
for Standard Line Security, Exit Time Restart is disabled. When a dialer is required for 06 minute check-in time, an
attack resistant enclosure (DMP Model 350A) is required. When the check-in time is set to a number less than 200
seconds, an attack resistant enclosure is not required.
To provide Encrypted Line security, install an XR500E panel or an XR500 panel with an iCOM-E™ Encrypted Network
Alarm Router.
ForEncryptedLinesecurityoperation,communicationbetweenthePremiseandSupervisingStationprovides128bit
encryption when using an XR500E panel or an XR500 panel with an iCOM-E Encrypted Network Alarm Router.
27.8 Wireless Audible Annunciation Option
The Wireless Audible option must be selected as ANY for commercial applications.
27.9 Model 463G or CellCom, CELL Only, Standard or Encrypted Line Security
Standard or Encrypted Line Security is provided when programmed using CELL with no backup. XR500 cellular
communication is used as primary with a 3 minute check-in when armed or disarmed.
Path 1 programming
Comm Type: = CELL Checkin: = 3 minute
Path Type: = Primary FailTime:=3minute
Encrypt: = NO or YES* Test Rpt: = NO
Sub Code: = NO or YES
*ForEncryptedLineSecurity,programaPassphraseinNetworkOptions.