Installation guide
Digital Monitoring Products XR500 Series Installation Guide
12
InstallatIon
Standby Battery Power Calculations Standby Current Alarm Current
736P POPIT Interface Module
Radionics Popex, POPITs, OctoPOPITs
Qty _______
Qty _______
x
x
25mA
___mA
______
______
Qty _______
Qty _______
x
x
25mA
___mA
______
______
738A Ademco Wireless Interface Module Qty _______ x 75mA ______ Qty _______ x 75mA ______
710 Bus Splitter/Repeater Module Qty _______ x 32mA ______ Qty _______ x 32mA ______
710F Fire Bus Splitter/Repeater Module Qty _______ x 40mA ______ Qty _______ x 40mA ______
711 Zone Expansion Module
Active Zone (EOL Installed)
Qty _______
Qty _______
x
x
11mA
1.6mA
______
______
Qty _______
Qty _______
x
x
11mA
*2mA
______
______
714 Zone Expansion Module
Active Zones (EOL Installed)
Qty _______
Qty _______
x
x
7mA
1.6mA
______
______
Qty _______
Qty _______
x
x
7mA
*2mA
______
______
712-8 Zone Expansion Module
Active Zones (EOL Installed)
Qty _______
Qty _______
x
x
17mA
1.6mA
______
______
Qty _______
Qty _______
x
x
17mA
*2mA
______
______
714-8, 714-16 Zone Expansion Module
Active Zones (EOL Installed)
Qty _______
Qty _______
x
x
20mA
1.6mA
______
______
Qty _______
Qty _______
x
x
20mA
*2mA
______
______
715 Zone Expansion Module
Active Zones (EOL Installed)
2-Wire Smokes
Qty _______
Qty _______
Qty _______
x
x
x
7mA
4mA
.1mA
______
______
______
Qty _______
Qty _______
Qty _______
x
x
x
7mA
*30mA
.1mA
______
______
______
715-8, 715-16 Zone Expansion Modules
Active Zones (EOL Installed)
2-Wire Smokes
Qty _______
Qty _______
Qty _______
x
x
x
20mA
4mA
.1mA
______
______
______
Qty _______
Qty _______
Qty _______
x
x
x
20mA
*30mA
.1mA
______
______
______
716 Output Expansion Module
Active Form C Relays
Qty _______ x 13mA ______ Qty _______
Qty _______
x
x
13mA
12mA
______
______
717 Graphic Annunciator Module
Annunciator Outputs
Qty _______ x 10mA ______ Qty _______
Qty _______
x
x
10mA
1mA
______
______
521LX, 521LXT Smoke Detectors Qty _______ x 8.8mA ______ Qty _______ x *28mA ______
572 Indicator LED Qty _______ x 20mA ______ Qty _______ x 20mA ______
iCOM, iCOM-E Network Alarm Routers Qty _______ x 78.1mA ______ Qty _______ x 78.1mA ______
Aux. Powered Devices on Terminals 7 and 11
Other than Keypads and LX-Bus Modules
______mA ______mA
This page only Sub-Total Standby
______mA Sub-Total Alarm ______mA
Sub-Totals from previous page Sub-Total Standby
______mA Sub-Total Alarm ______mA
*Based on 10% of active zones in alarm Total Standby ______mA Total Alarm ______mA
Total Standby______mA x number of Standby Hours needed
Total Alarm
______ =
______mA
Total
_______mA-hours
+_______mA-hours
_______mA-hours
X .001
= _______Amp-hrs Required
Refer to section 6.9 for standby battery selection.