Installation guide
Digital Monitoring Products XR500 Series Installation Guide
6
IntRoduCtIon
3.4 Accessory Devices (continued)
DMP Two-Way Wireless Devices (continued)
* 1131 Recessed Contact Provides a recessed contact option for door or window applications.
* 1139 Bill Trap Provides a silent alarm option for retail and banking cash drawers.
1142BC Two-button Hold-up Belt
Clip Transmitter
Provides two-button hold-up operation with a belt clip.
1142 Two-button Hold-up
Transmitter
Provides permanently mounted under-the-counter two-button hold-up operation.
*1145(Four-Button)
* 1146 (Two-Button)
* 1147 (One-Button)
KeyFobtransmittersdesignedtoclipontoakeyringorlanyard.
1161 Residential Smoke Detector Residential smoke detector with sounder.
1162 Residential Smoke/Heat
Detector
Residentialsmoke/heatdetectorwithsounderandxedrate-of-riseheatdetector.
1165 Commercial Smoke
Detector
Commercial smoke detector.
1165H Commercial Smoke/Heat
Detector
Commercialsmoke/heatdetectorwithxedrate-of-riseheatdetector.
1165HS Commercial Smoke/Heat
Detector and Sounder
Commercialsmoke/heatdetectorwithxedrate-of-riseheatdetectorandsounder.
1181 PIV Commercial Post Indicator Valve (PIV)
1182 OS&Y Commercial Outside Screw and Yoke Valve (OS&Y)
* This device has not been investigated and shall not be used in listed installations.
Indicating and Initiating Devices
865 Supervised Style W or X
NoticationCircuitModule
Provides supervised alarm current when using the XR500 Series panel bell output and up to
5 Amps at 12 or 24 VDC when using a listed auxiliary power supply. The 865 can supervise
2-wire or 4-wire style circuits for opens and shorts with individual LED annunciation.
866StyleWNoticationCircuit
Module
Provides supervised alarm current using the XR500 Series panel bell output and up to 5 Amps
at 12 or 24 VDC when using a listed auxiliary power supply. The 866 can supervise 2-wire
Style W circuits for opens and shorts.
867StyleWLX-BusNotication
Circuit Module
Provides supervised alarm current using the XR500 Series panel bell output and up to 5 Amps
at 12 or 24 VDC when using a listed auxiliary power supply. The 867 connects to the XR500
SeriespanelLX-Bus™andprovidesone2-wireStyleWnoticationcircuitforopenandshort
conditions. Individual Bell Relay addresses Bell Ring styles.
869 Dual Class A Style D
Initiating Module
ProvidestwoClassA,StyleD,4-wireinitiatingzonesforconnectingwaterowswitchesand
othernon-poweredreandburglarydevices.
Accessory Modules and Keypads
893A Dual Phone Line Module Allows you to supervise two standard phone lines connected to an XR500 Series panel. The
893A module monitors the main and backup phone lines for a sustained voltage drop and
alerts users when the phone line is bad.
* ePAD™ Virtual Keypads Allows users to control the security system from any computer using the Internet.
iCOM™ Network Alarm Router Allows the XR500 panel to send signals through the Internet/Ethernet.
iCOM-E™ High-Security Network
Alarm Router
AllowtheXR500paneltosendencryptedsignalsthroughtheInternet/Ethernet.Foruse
when the Advanced Encryption Standard (AES) Encryption Algorithm is required. The iCOM-E
isNISTcertied.
LCD keypads Allows you to control the panel from various remote locations. Connect up to sixteen
supervisedModel630FRemoteFireCommandCenter,Model690,790,693/793Security
Command™ keypads, 7060, 7063, 7070, 7073, 7160, 7163, 7170, 7173 Thinline™ keypads,
7060A, 7063A, 7070A, 7073A Aqualite™ keypads, or 7760 Clear Touch™ keypad to the keypad
bus using terminals 7, 8, 9, and 10.
Addressable Smoke Detectors
521LX, 521LXT Single-zone, addressable conventional smoke, smoke/heat detectors that connect to the
LX-Bus. Includes remote maintenance reporting, drift compensation, and multi-criteria
detection.
* This device has not been investigated and shall not be used in listed installations.