Installation guide

1912XR Installation Guide
Digital Monitoring Products, Inc. 1912XR Installation Guide
Page 1
Panel Specifications
1.1 Power supply
Transformer Input: 16.5 VAC or 40VA (Models 320 or 321) or 100VA (Model 322).
Standby Battery: 12 VDC 6.5Ah (40VA charges two batteries, 100VA charges three or four batteries))
Auxiliary Output: 12 VDC at 600mA with 40VA transformer
Bell Output: 12 VDC at 1 Amp
Inherent Power Limited
1.2 Communication
Built in Dialer communication to DMP Model SCS-1 Receivers
Built in Multiplex communication to DMP Model SCS-1 Receivers
Built in DDMX communication to DMP Model SCS-1 Receivers
Built in CID communication to non-DMP receivers
Optional Model 893 Dual Phone Line Module with phone line supervision
Can operate as a local system
1.3 Panel loops
Four 1K EOL burglary loops (loops 1 to 4)
One 3.3K EOL Class B powered loop with reset (loop 5)
1.4 Keypads and expanders
You can connect up to eight of the following keypads or expanders to the 1912XR keypad data bus:
670, 770, or 771 Alphanumeric Keypads
711, 714, and 715 Loop Expanders
5845LX Glassbreak single point detector
6155LX PIR single point detector
You can connect the following devices to the LX-Bus of the Model 862N, 862P, 872, and 881 Interface
Cards up to the maximum number of addresses. Also see Accessory Devices in section 4.1.
714 and 715 Loop Expanders - up to 25 devices
716 Output Expander - up to 25 devices
5845LX Glassbreak single point detector - up to 100 devices
6155LX PIR single point detector - up to 100 devices
The 714 and 715 Loop Expanders each provide four loops.
The 716 Output Expander provides four Form C relays (SPDT) and four 50mA switched grounds (open
collector) suitable for a variety of annunciation and control applications.
1.5 Output contacts
Two on-board auxiliary Form C outputs. See section 13.1. You can have up to 100 additional outputs when
using 716 Output Expanders and an 862N, 862P, 872, or 881 Interface Card.
Outputs require two Model 305 relays, each rated for 1 Amp at 30 VDC or 0.5 Amp at 120 VAC
The panel also provides four auxiliary voltage outputs rated for 50mA at 12 VDC. See section 14.1.
1.6 Enclosure specifications
The 1912XR is shipped installed in its enclosure with end of line resistors, battery leads, and programming
sheets.
Size: 12.5" x 11.5" x 3.0"
Weight: 6 lbs
Color: Black (61) or Grey (63)
Construction: 18 gauge cold rolled steel