Specifications

3.2 Repeaters
Network Modules 3–7
Media
Sixteen 8-pin MJ unshielded twisted-pair (UTP) connectors.
LAN Connectivity
Both a ThinWire BNC and an attachment unit interface (AUI) available when
installed in the Digital MultiStack System.
One backplane ThinWire when installed in a DEChub 900 MultiSwitch.
One backplane ThinWire when installed in a DEChub 90.
One ThinWire BNC when standalone.
Upgrade Method
Not field upgradable.
Manageability
Digital MultiStack System—Requires the DECagent 90, the DECrepeater 90TS,
or DECrepeater 90FS as the stack manager for local and remote management.
DEChub 900 MultiSwitch—Managed through the integral hub management
agent.
DEChub 90—Requires the DECagent 90, the DECrepeater 90TS, or DECrep-
eater 90FS for local and remote management
DEChub ONE—Not installable.
DEChub ONE-MX—Not installable.
Standalone—Not manageable.
Supported MIBs
Ethernet MIB (RFC 1398)
Repeater MIB (RFC 1516)
Digital Extended Repeater MIB
MIB II (RFC 1213)
IP Service
Not an IP Services provider.