Specifications

6.6 Case 5: Collapsed Fiber Optic (Campus) Ethernet Backbone
6–14 Configuration Examples
6.6 Case 5: Collapsed Fiber Optic (Campus) Ethernet
Backbone
Goal
Design a collapsed fiber optic campus backbone. This is similar to Case 4, but there
is no fiber optic redundancy, allowing the use of a DECswitch 900FO. Groups are
spread across multiple buildings. FDDI shared backbone is a likely future migration.
Design Requirements
A centralized functional department is located in its own building, with shared
services and bridging between all LANs in the building.
A central campus backbone with WAN access.
A fiber optic campus backbone connection to 3 other buildings.
Network management.
Suggested Configuration - Central Department:
This configuration is similar to Case 3.
Platform type: Use a DEChub 900 MultiSwitch to support a mixture of half-
height and full-height modules and provide the integral management agent.
Network Modules:
DECswitch 900FO
DECbrouter 90T1
DECserver 900TM
DECrepeater 90C
DECrepeater 90T16
Suggested Configuration - Building 1:
This configuration is similar to Case 2.
Platform type: DEChub 90
Network Modules:
DECrepeater 90FA
–DECagent 90