9. THERMAL SPECIFICATIONS
9.1. Thermal Analysis for Case Integration
Since the integrated heat sink is uni-directional, the airflow must be exactly in the direction of the heat rails. If
possible, mount the board vertically, so that the heat rails are up/down. In this case, the self produced airflow
is about 3m/sec.
Pay particular attention when mounting the PC-product in a fully enclosed case/box. The thermal energy will
be stored in the interior of this environment.
If the case has a fan:
The hot air must be exchanged with cool air from outside using a filtered fan.
The hot air must be cooled with a heat exchanger.
If the case has no fan or opening to exchange the hot air:
The heat sink of the CPU must be mounted directly to a heat sink integrated into the case. The
thermal energy does not go through the air; the heat will be conducted directly through the alloy of the
heat sink to the outside.