User`s guide
5-14 DL600E E1 Data Multiplexer UserÕs Guide
ConÞguring the Data Ports
Use DATA 1 CONFIG, DATA 2 CONFIG, DATA 3 CONFIG, and so on to
conÞgure data ports
. Refer to ÒConÞguring the Data PortsÓ in Chapter 3
for a description of the parameters.
To conÞgure the data ports:
1 From the CONFIGURATION menu, press ENTER and open DATA
1 CONFIG
using the Up or Down Arrows and ENTER.
DATA 1 NORMAL appears. (NORMAL is the default code.)
2 Press the Down Arrow to move to the next parameter, LOS.
DATA 1 LOS,RTS appears. RTS is the default LOS parameter.
3 Press ENTER to activate edit mode.
RTS
starts to blink.
(Or press
EXIT to take no action and move to the next item)
Press the
Up or Down Arrows to cycle through the available LOS
options and press
ENTER to select an option.
4 ConÞgure the mode, format and clock for data port 1 using this
method. Repeat for the other data ports using the appropriate
menu for the data port.
Allocating Timeslots
Use the TIMESLOT CONFIG menu to view and allocate network
timeslots. The default timeslot allocation is all
24 time slots allocated to
port 1 Ñ
If you make an incorrect selection, the system responds with an error
message, such as
ERR DTE01 DTE02
For information on allocating timeslots refer to ÒAllocating TimeslotsÓ
in Chapter 3.
DTE01 TS = 01 -- 31