User`s guide

5-10 DL600E E1 Data Multiplexer UserÕs Guide
The Comm Port Settings
The Comm Port parameters are: BAUD RATE, PARITY, WORD LENGTH,
STOP BITS, ENABLE DCD,
and XOFF UNTIL.
The front panel displays one parameter and its current value.
To view and modify the Comm Port settings, follow the procedure in
the example below:
1 From the CONFIGURATION menu, press ENTER to move down to
the
UNIT CONFIG menu.
2 Press ENTER to open the UNIT CONFIG menu.
The
UNIT ID parameter appears, for example:
UNIT ID HARRY_
3 Select the COMM PORT CONF submenu using the Down Arrow
and ENTER.
BAUD RATE 9600 appears.
Press
ENTER to activate edit mode. (9600 starts to blink.)
4 Cycle through the available baud rate options using the Up or
Down Arrow and press ENTER to select an option.
Press
ENTER again to conÞrm the change when the system
prompts:
TO CHANGE CONFIG
YES--ENTER, NO--EXIT
or press EXIT to exit without executing the baud rate change.
5 To move to the next Comm Port parameter, press the Up or
Down Arrow
.
Use the method described above to edit the parameter.
6 Power cycle the unit to execute changes.
BAUD RATEBAUD RATE 9600