User`s guide
4-6 DL600E E1 Data Multiplexer UserÕs Guide
Logging Off
To log off, press Ctrl-x.
You are logged off when the terminal stops responding to keystrokes.
Monitoring Status
Monitor the status of the DL600E unit from Menu-1 Main Status and the
status of its data ports from
Menu-2 Data DTE Status.
Figure
4-1 shows an example of Menu-1 Main Status. The remote unit is
a
DL600E unit with an AUX port.
SW Ver 1.0 MIB Ver 1.2 Digital Link DL600 Encore 4/22/95
HW Ver A Menu-1 Main Status 12:56:28
Local: OAHU Remote: MAUI
Unit Status No Clock Normal
Payload Loopback(FULL)
Network Status Normal RAI Received
AUX DTE Status Normal
DATA DTE Status Loss of Signal Normal
Alarm Input Status Temperature Alarm on Normal
Error Free Seconds 100.0% 96.5
CRC4 Errors 23 654
Code Violations 255 325
Frame Error Events 1
Seconds In Current 15 Min. 421 21
Errored Seconds In Interval 0 2
0-SNMP Config. 1-Main Status 2-Data DTE Status 3-Reports 4-Main Config.
5-Data Port Config. 6-Timeslot Config. 7-Alarm I 8-Alarm II 9-Diagnostics
Type C to clear the counters or type 0 through 9 for a new menu:
Figure 4-1 Menu-1 Main Status
To clear the counters, press c.
Press
y to conÞrm after the system prompt:
Do you really want to clear the error counters (Y/N)?
(or press any other key to take no action.)
Any status related to the counters may take up to a minute to clear.
Values for
CRC Errors and Code Violations are set to 0.