3-28 DL600E E1 Data Multiplexer UserÕs Guide
SW Ver 1.0 MIB Ver 1.1 Digital Link DL600 Encore 4/22/95
HW Ver A Menu-8 Alarm II 12:56:56
Local: OAHU Remote: MAUI
External Alarm Input Indication Disable
External Alarm Input Contacts Normally Closed
External Alarm Input Message
External Alarm Output Indication Disable
External Alarm Output Contacts Normally Closed
Connection In-Band Commmunications Modem
Timeout When Logged On 1 Min 15 Min
Timeout When Not Logged On 1 Min Unlimited
Phone Number 1 ATDT9,1-408-524-7433 ATDT9,1-408-745-6200
Phone Number 2 ATDT9,1-408-524-7622 ATDT9,1-408-745-6200
Normal User Password **
Superuser Password **
COMM DCD Enabled Enabled
XON/XOFF Disabled XOFF until Any
0-SNMP Config. 1-Main Status 2-Data DTE Status -Reports 4-Main Config.
5-Data Port Config. 6-Timeslot Config. 7-Alarm I 8-Alarm II 9-Diagnostics
Type Arrow keys to move the selection, RETURN to change a selection
or type 0 through 9 for a new menu:
Figure 3-7 Menu-8 Alarm II
Menu-8 Alarm II Parameters
External Alarm Input IndicationÑEnabled, Disabled
(DefaultÑDisabled)
Appears on the menu only when the remote unit is a DL600E unit
and applies only to it.
Select
Enabled to receive alarms from an external source (such
as a door opening or a burglar alarm).
External Alarm Input ContactsÑNormally Open, Normally
Closed (DefaultÑNormally Open)
Appears on the menu only when the remote unit is a DL600E unit
and applies only to it.
Select
Normally Open or Normally Closed depending on how the
mechanism from the external source (such as a door opening or
a burglar alarm) is set.
SW Ver 1.0 MIB Ver 1.1 Digital Link DL600E 4/22/96