ConÞguring the DL600E Unit 3-21
ConÞguring for SNMP
ConÞgure each unit for SNMP management functionality in Menu-0 SNMP
ConÞg.
In the example in Figure 3-5 the remote is a DL600E unit, a Solo E1 DSV unit, or
a Solo E1 Ensemble Shelf Module
.
SW Ver 1.0 MIB Ver 1.1 Digital Link DL600 Encore 4/22/95
HW Ver A Memu-0 SNMP Config. 12:56:56
Local: OAHU Remote: MAUI
UNIT SNMP
Disabled Disabled
IP Address 0.0.0.0 0.0.0.0
IP Mask 0.0.0.0 0.0.0.0
Forward Over IBC Disabled Disabled
TRAP 1st NMS IP Address 0.0.0.0 0.0.0.0
2nd NMS IP Address 0.0.0.0 0.0.0.0
3rd NMS IP Address 0.0.0.0 0.0.0.0
Output Port COMM IBC
Community Strings
Get
public public
Set public public
Trap public public
0-SNMP Config. 1-Main Status 2-Data DTE Status 3-Reports 4-Main Config.
5-Data Port Config. 6-Timeslot Config. 7-Alarm I 8-Alarm II 9-Diagnostics
Type Arrow keys to move the selection, RETURN to change a selection
or type 0 through 9 for a new menu:
Figure 3-5 Menu-0 SNMP ConÞg.
SNMP Parameters
Unit SNMPÑEnabled or Disabled (DefaultÑDisabled)
EnabledÑEnables use of a SNMP management application.
IP addressÑnnn.nnn.nnn.nnn (DefaultÑ0.0.0.0)
nnn = 0 through 255
Enter the DL600E IP address. ExampleÑ192.84.33.6
IP MaskÑnnn.nnn.nnn.nnn (DefaultÑ0.0.0.0)
nnn = 0 through 255
Enter the DL600E IP mask. ExampleÑ255.255.255.0