3-14 DL600E E1 Data Multiplexer UserÕs Guide
The system prompts (if s or d is chosen):
Please start the XMODEM download.
Type CTRL-X to abort.
4 From the terminal, select XMODEM transmission and specify
the Þlename of the new software on the diskette.
5 The system informs you of a successful or unsuccessful
operation. In each case (including a cancelled operation), it
prompts:
Please type Y to reset the unit. [Y]:
Type
y to reset the unit.
The system prompts:
Please wait... Unit is being reset.
System Messages and Error Indicators
During the operation, integrity check results are indicated by OK or
BAD in the DOWNLOAD UTILITY menu:
DOWNLOAD UTILITY 0.1
Operational Software:
OK
Updated Download Utility: OK
Factory Download Utility: OK
Download RAM allocated: OK
In the case of the Þrst three items, the operation has proceeded correctly
even when Ò
BADÓ appears.
Operational SoftwareÑ
BAD indicates the DL600E operational software
stored in the
FLASH failed either its CRC check or unused FLASH was
not set to the expected value.
Updated Download UtilityÑBAD indicates the DL600E download utility
stored in the
FLASH failed either its CRC check or unused FLASH was
not set to the expected value.
Factory Download UtilityÑBAD indicates the DL600E factory-installed
download utility stored in the
FLASH failed either its CRC check or
unused
FLASH was not set to the expected value.