Connecting a Terminal Through a Modem
To connect a terminal to the DL600E unit through a modem, use a null
modem cable.
D Note: Digital Link can provide 9-pin to 25-pin adapters, or a
null-modem adapter if required.
It is recommended, though not required, that Connection be set to
Modem in Menu-8 Alarm II.
If the Comm Port baud rate is
9600, the distance between the DL600E
unit and the modem cannot exceed
50 feet (15.25 meters). If the baud
rate is less, the distance can be increased.
To connect a modem to the
DL600E Comm Port:
1 Make sure the connection is a crossover (null) modem
connection.
2 Make sure the DL600E baud rate, parity bit and stop bit
settings match those of the modem.
If they do not, change the settings on the modem to match the
DL600E unit.
3 Connect the modem to the DL600E DE9 connector shown in
Figure
3-1.
4 Connect the modem to the phone line and the terminal.