User`s guide
Installing the DL600E Unit 2-3
Network port interface cable
Cables with DA15 plug connector
or
Cables with
DA15 plug connector on one end and BNC connector
on the other end for coaxial interface
Coaxial cable for BNC connectors
The send and receive pairs of the E1 cable are shielded separately
to minimize crosstalk
Power cord
AC power cord ordered from Digital Link for an AC model
or
Customer-supplied power cable (14 AWG, 3 conductors, copper-
strand wire, type TC) for a DC model
Customer-supplied grounding cable
Cable used to connect DL600E unit to earth ground
Customer-supplied ANSI terminal
For conÞguring DL600E unit
Equipment Model Numbers
The Digital Link model numbers related to the DL600E unit are listed
in Appendix
A. Cable and connector pinout assignments are listed in
Appendix
B.
Gathering Information
To establish a Telnet connection to the DL600E unit, you must specify
the DL600E
IP address and IP subnet mask. To use an SNMP
network management station, you must specify the DL600E
IP
address
and IP subnet mask and one to three NMS IP addresses.
You must do this from the terminal interface. Refer to
Chapter 3
ConÞguring the DL600E from a Terminal
for further information about
the terminal interface.
Your network administrator should give you this information about the
remote terminal before you begin the installation.