User`s guide

Technical SpeciÞcations A-3
Front Panel
Display 16 character alphanumeric
Key Pad 4 keys
LEDs (per data port) TD, RD, CTS, RTS, DTR, DATA/TEST
Status Network Port, E1 Port, Test
Bantam Jacks E1 Send (IN/MON), E1 Receive (MON)
Power Options
AC Input Voltage 120 to 220 VAC, 50 to 60Hz
DC
Input Voltage -48VDC (optional)
Power Consumption 10W maximum
Physical
Dimensions 43.2cm W x 30.5cm D x 4.37cm H
(17"W x 12" D x 1.75"H)
Environmental
Operating temperature 0 to 50° C
Relative humidity 0 to 95% non-condensing
Altitude 4.6 km (15,000 ft. ASL) Reliability and Equipment Life
MTBF 13 years minimum
MTTR 30 minutes maximum
Diagnostics and Tests
Loopbacks E1 Network, E1 Payload, DTE, Fractional E1 Payload,
Fractional
DTE
E1
Loopback Control E1 Set/Reset Code, front panel, Comm Port, SNMP
Fractional Payload
Loopback Control CCITT V.54 Sequence, Comm Port
Test Patterns QRW, 1-in-1, 1-in-7, 3-in-24, All 1s, All 0s, 1-in-2, 1-in-4, and 2
user-programmable patterns
SNMP
Full embedded SNMP agent based on SNMP v1, supporting RFC 1406,
MIB II, with enterprise MIB.
Supported SNMP trapsÑNetwork Carrier Loss, Network Sync Loss,
Network UA1 Received, Network RAI Received, Loss of DTE, Start of
Test, End of test, CV Error Threshold Exceeded, CRC4 Error Threshold
Exceeded.