User`s guide
Diagnosing the DL600E Unit 6-3
User
selectable
Test
status
parameters
Selected test
The Diagnostics Menu
When running a test, you can:
¥ Initiate loopbacks and tests on the full bandwidth or on the
data port fraction
¥ Set programmable test patterns
Figure Figure 6-1 shows an example of Menu-9 Diagnostics.
SW Ver 2.0 MIB Ver 1.2 Digital Link DL600 Encore4/22/95
HW Ver AMenu-9 Diagnostics00:00:36
Local: MARS Remote: VENUS
Current TestPLD Lpbk(FULL) Idle
Pattern Test StatusIdle Idle
Last Self Test ResultSelf Test PassedSelf Test Passed
CRC4 Errors0 5
Code Violations0 5 18
Pattern Error Counter------------------------
FractionFull Bandwidth DATA3
Test Length1 Min. 15 Min.
TestLoop Payload DTE Loopback
Full Bandwidth Loop CodeStandard Standard
Fractional Loop CodeV.54 Disabled
USER1 Pattern0011001100110011001 10011 10011
USER2 Pattern000100010001000100010001 001001000
LOCAL ID=MARS Payload Loopback Test (Full BW) start at 16:08 May 22, 1995
0-SNMP ConÞg. 1-Main Status 2-Data DTE Status 3-Reports 4-Main ConÞg.
5-Data Port ConÞg. 6-Timeslot ConÞg. 7-Alarm I 8-Alarm II 9-Diagnostics
Arrow keys move the selection, RETURN changes a selection, S starts a test,
E ends a test, C clears the Pattern Error Counter, 0 through 9 start a new menu.
Figure 6-1 Menu-9 Diagnostics
Loop Payload