6-2 DL600E E1 Data Multiplexer UserÕs Guide
Running Diagnostic Tests
To verify the connections and E1 line, run the following basic diagnos-
tic and pattern tests from Menu-9 Diagnostics:
¥ Loop
DTE test
¥ Loop
NET test
¥ Loop Local AUX E1
¥ Loop Payload test
¥ Loop Up Remote test
¥ Loop Down Remote test
¥ Various Pattern tests
You can also run these tests from the front panel. Refer to ÒUsing the
TEST MenuÓ in Chapter 5 for further information. Refer to Chapter 3
for further information about connecting a terminal to the DL600E unit.
You can initiate the tests and loopbacks on the full bandwidth or on the
data port fraction. You can also set programmable test patterns.
D
Note: You do not need to inform the telephone company
you are running the tests. However, if the tests reveal a
problem with telephone company service or with the
DL600E unit, you should inform the telephone company
that the
DTE equipment or the DL600E unit must be
removed from service.