User guide
Diagnostics 5-3
5
4. Type y for yes and the test will begin.
The tests available in the Next Test parameter are shown in Table 5-2.
Table 5-1 Meru-9 Diagnostic Parameters
Parameter Value Description
Pattern Test Status Idle
Searching
Locked
Relocked
Locked Seconds is displayed if the current pattern test
is locked. The Locked Seconds is a 16-bit counter
which is reset to 0 if the current pattern is unlocked.
The counter label will change to Relocked Seconds if
the current pattern is unlocked and then relocked.
Pattern Error Counter Error count Shows number of errors encountered.
CRC4 Errors Error count Shows number of errors encountered. If CRC4 is not
enabled, this function is not available.
Code Violations Error count Shows number of errors encountered.
Frame Error Events Error count Shows number of errors encountered.
Last Self Test Result Self Test Passed
Failure indication: 0-5
Error nn (0 to 5). See Table 5-4 on page 5-5 for
discussion of error codes.
Table 5-2 Next Test Diagnostics
Shortcut Test Options
1 Self Test See “Self Test” on page 5-4
2 DTE Lpbk FULL, DATA01
3 NET Lpbk FULL, DATA01
4 PLD Lpbk FULL, DATA01
5 LP UP Remote FULL, DATA01
6 LP DN Remote FULL, DATA01
7 Send QRW FULL, DATA01
8 Send 1:7 FULL, DATA01
9 Send 3:24 FULL, DATA01
10 Send 1:1 FULL, DATA01
11 Send All 1s FULL, DATA01
12 Send All 0s FULL, DATA01
13 Send 1:2 FULL, DATA01
14 Send 1:4 FULL, DATA01
15 Send User 1 FULL, DATA01