User guide
3-18 Solo E1 DSU User Guide—June 1998
3
DATA port alarm condition recognizes and reports the loss of DTE, by
setting the Solo E1 DSU to recognize loss of RTS or loss of DTR.
Use Menu-7 Alarm I to set the alarm conditions (Figure 3-7).
Figure 3-7 Menu-7 Alarm I
Setting alarm I parameters is optional.
Table 3-6 describes the parameters of Figure 3-7.
Table 3-6 Menu-7 Alarm I Parameters
Parameter
(Default) Settings Description
Block All Alarms
(No)
Yes
No
Yes—Blocks the reporting of alarms.
No—Enables the Solo E1 to report alarms.
NET Carrier Loss
Alarm
(Enabled)
Enabled
Disabled
Enabled—The Solo E1 generates an alarm
when a Network Carrier Loss of Signal occurs.
Disabled—Disables the function.
NET Sync Loss
Alarm
(Enabled)
Enabled
Disabled
Enabled—The Solo E1 generates an alarm
when a Network Sync Loss occurs.
Disabled—Disables the function.