User guide

Configuration 3-17
3
Menu-7 Alarm I Conditions
Alarm conditions are categorized as network and DATA port alarm
conditions. Alarm conditions affecting network or DATA port signals are
reported on the terminal user interface and through SNMP.
For information on reports and event logs, refer to ÒCheck EfÞciency with
Menu-3 Performance ReportsÓ on page 4-6.
The Solo E1 DSU recognizes and reports the following network alarm
conditions:
¥ Loss of carrier signal
¥ Loss of network synchronization
¥ Threshold violations
¥ Unframed All Ones
¥ Remote Alarm Indication
TRAP NMS IP Address
(0.0.0.0)
(applies to 1st, 2nd and
3rd TRAPS)
nnn.nnn.nnn.nnn nnn—0 through 255. Enter the IP address of the NMS
(Network Management Station) that will receive trap
messages from the Solo E1 DSU SNMP agent.
(Note: If all the TRAP NMS IP addresses are set, the Solo
E1 sends a trap to all three network management
servers.)
TRAP Output Port
(COMM)
COMM
IBC
Select the port that the Solo E1 DSU SNMP agent uses
to send TRAP messages to the NMS.
Get
(public)
text string Enter an alphanumeric text string (maximum—32
characters). The Solo E1 DSU SNMP agent uses this text
string to check GET requests for the SNMP configuration
from the NMS.
Set
(public)
text string Enter an alphanumeric text string (max—32 characters).
The Solo E1 DSU SNMP agent uses this text string to
check SET requests from the NMS to set the SNMP
configuration.
Trap
(public)
text string Enter an alphanumeric text string (maximum—32
characters). The Solo E1 DSU SNMP agent inserts in
SNMP TRAPs it sends to the NMS.
Table 3-5 Menu-0 SNMP Config. Parameters (Continued)
Parameter
(Default) Settings Description