User guide
Configuration 3-15
3
a. Select Manual.
Do you really want to change the configuration [Y/N]?
b. Select y for yes.
2. Allocate by timeslot:
a. Press enter to select timeslot 1.
This highlights Local D01 on the Network Time Slot Map.
3. Press enter, and D01 will begin blinking.
Type the UP or DOWN arrows to change the selection, or type
a port number (NN or I for IDLE):
4. Type i (for IDLE)
Timeslot 1 displays a dashed line starts to blink.
a. Press enter and then you receive the prompt:
Do you really want to change the configuration [Y/N]?
5. Type y for yes.
Menu-0 SNMP Configuration
To conÞgure the Solo E1 DSU for SNMP management capability, use
Menu-0 SNMP ConÞg.
Have an IP address for the Solo E1 DSU and the NMS (Network
Management Station) that receives TRAP messages.
The GET, SET, and TRAP community strings function as passwords, and
prevent another SNMP management station from gaining access to the Solo
E1 DSU.