3-14 Solo E1 DSU User Guide—June 1998
3
b. Press the enter key to activate edit mode.
Type a port number (NN for a data port, I for Idle, or the
UP or Down arrow):
c. Type 1
For DATA port 1. (You can specify only port 1.)
d. Press the enter key.
Menu-6 displays DATA01 in Allocate by Port (Þrst Þeld).
At the bottom of the screen you will see:
Type the start timeslot (NN), or 0, or I for IDLE or the UP
or DOWN arrows:
3. Set the start and end timeslots:
a. Type 1 and press the enter key to set the start timeslot to
1.
Menu-6 displays DATA01 TS01. The end timeslot Þeld blinks.
Please type the end timeslot (NN):
b. Type 14, press the enter key, and type y to set the end
timeslot to 14.
Allocate by Port displays DATA01 TS01-TS14 896 Kb/s
timeslots 1 through 14 are allocated to port 1; all other slots are
idle.
OR
If a remote unit is attached, you will get the following message:
Do you want to change the local unit, the remote, or both
(L, R, or B):
i. Press r for remote.
Do you really want to change the conÞguration? [Y/N]
c. Press y for yes.
Allocating Timeslots Manually
In this example, you will set timeslot to Idle mode. All timeslot are
conÞgured individually using the same procedure.
1. Edit the Allocation Type parameter.