User guide
2-12 Solo E1 DSU User Guide—June 1998
2
A bare, covered or insulated grounding conductor is acceptable. A
conductor that is individually covered or insulated should have an outer
Þnish that has a green continuous outer Þnish, or green with one or more
yellow stripes.
Cable Connections
To connect the Solo E1 DSU (Figure 2-5):
1. Connect the DTE cable (refer to Table 2-7):
a. Connect the DTE cable to the Solo E1 DSU DB-25 socket
connector.
b. Connect the opposite end to the DTE equipment.
2. Choose your network connection, either (refer to Table 2-6):
Socket:
a. Connect the network cable to the Solo E1 DSU DA-15
socket connector.
b. Connect the opposite end to the NET equipment.
BNC:
a. Connect a coaxial cable from the Solo E1 DSU RX BNC to
your network TX connector.
b. Connect a coaxial cable from the Solo E1 DSU TX BNC to
your network RX connector.