User guide

4-24 DL3800 DS1 Inverse Multiplexer User Guide—February 1999
4
To change the number of errored consecutive seconds that will cause that
T1 line to go out of service, highlight the appropriate item and press
Enter. When the highlight bar is blank, type in the number of seconds
desired.
The INTERVAL THRESHOLDS section of this menu allows the user to
enable or disable the FALLBACK feature. FALLBACK relates to the
number of in-error seconds (from 1 to 900) occurring in a 15-minute period,
or the number of in-error 15-minute intervals (from 1 to 96) occurring in a
24-hour period that will cause a MAJOR or MINOR alarm. To Enable or
Disable the FALLBACK feature, highlight the appropriate item and use the
space bar to select your choice. To change the number of in error seconds
or 15-minute intervals that will cause a MAJOR or MINOR network alarm,
highlight the appropriate item and press Enter. When the highlight bar
is blank, type in the number desired.
Save Configuration
This option allows the user to manually back up the database to EEPROM
at any time. To Save ConÞguration and back up the database to EEPROM,
highlight the Save Configuration in the CONFIGURATION MENU, and
press the Enter key.
System Utilities
The SYSTEM UTILITIES MENU in the INVERSE MULTIPLEXER MAIN
MENU is used to access Sub-Menus in the DL3800 to conÞgure various
system utilities and perform certain functions with the DL3800. These
System Utilities include Software Download, Delete Entire Node
ConÞguration, Login ConÞguration, SNMP ConÞguration, and Save
ConÞguration.
To access the SYSTEM UTILITIES MENU, highlight System Utilities in
the INVERSE MULTIPLEXER MAIN MENU, and press the Enter key.
Figure 4-13 is an example of the SYSTEM UTILITIES MENU that will
appear. To access any of the Sub-Menus or perform certain functions,
highlight that line item, and press the Enter key.
NOTE: Default settings are shown in Figure 4-12