4-16 DL3800 DS1 Inverse Multiplexer User Guide—February 1999
4
DTE Configuration
This menu allows the user to conÞgure certain parameters of the DTE,
including the interface type, clock source, status of leads and loss criteria.
To access the DTE CONFIGURATION MENU, move the highlight bar to
DTE CONFIGURATION in the CONFIGURATION MENU, and press Enter.
Figure 4-10 is an example of the DTE CONFIGURATION MENU, and
Table 4-6 describes the menu items.
Figure 4-10 DTE CONFIGURATION MENU
Table 4-6 DTE CONFIGURATION MENU Options
Parameter Description/Action
DTE Interface This allows the user to select V.35, RS449, or HSSI as the DET Interface.
To change the present DTE Interface, use the up and down arrow keys to
highlight DTE Interface. Use the Space Bar to toggle between V.35,
RS-449, and HSSI until the desired choice appears. Highlight Confirm,
and press the Enter key to confirm the change. (Default - V.35)