User guide

4-4 DL3800 DS1 Inverse Multiplexer User Guide—February 1999
4
INVERSE MULTIPLEXER MAIN MENU COMMANDS
When a DL3800 is Þrst powered up, the Main Menu (Figure 4-1 on page 4-
3) appears on the terminal screen. This describes those functions that can
be performed, parameters viewed, changed and/or deleted from this
menu. The INVERSE MULTIPLEXER MAIN MENU items are shown in
Table 4-1.
These items are described in more detail in the following sections.
SELECT LOCAL/REMOTE
When in the INVERSE MULTIPLEXER MAIN MENU, this option allows
the user to view and access the other items on either the local or remote
DL3800. The Device Address and Name in the header portion of the
display screen will identify the unit that the terminal is presently
communicating with.
To move to the Main Menu of the other DL3800, highlight
SELECT
LOCAL/REMOTE and press Enter. The Device Address and Name in the
header should change to the new unit as shown in Figure 4-2.
Table 4-1 Main Menu
Menu Description
Select Local/Remote Allows the user to move between the Main Menu of the Local and
Remote units.
Alarms and Status Provides current alarm and status report of the common equipment, DTE,
and T1 lines.
Statistics Allows the user to access the statistics menus of the various T1 lines.
Event History Allows user to view and clear alarms and event history of the DL3800.
Configuration Allows the user access Sub-Menus to configure certain parameters of the
DL3800, network, and DTE.
System Utilities Allows the user to perform various system utility functions such as
download software, configure SNMP, configure login, and delete or save
configuration.
Tests Allows the user to initiate diagnostic loopbacks.
Manual Network Restoration Allows the user to manually restore a T1 circuit instead of it being
restored automatically upon the clearing of a problem.
Logout Allows the user to log out of the DL3800 without having to wait for
automatic logout.