User guide
1-2 DL3800 DS1 Inverse Multiplexer User Guide—February 1999
1
¥ HSSI or 155-10082-01(HSSI) (Model DL1404-10)
¥ M-34 to DB-25 cables(V.35) or 155-00903-01(V.35) (Model DL1300-10)
¥ DC-37 to DB-25 (RS-449)155-00902-01(RS449) (Model DL1302-10)
Setup
Terminal Log on
Connect your terminal to the COMM port on the back of the DL3800.
Before you can log into the unit, you must make sure that terminal settings
match the DL3800. Defaults for the DL3800 COMM port: 9600 Baud rate,
no parity, 8 bit word length, 2 stop bits. To log into the unit, Þrst press
Ctrl-X 5 times (ie, hold down control key on terminal and press X Þve
times). This gives you the unit number. Now type Ctrl-X # Unit
Number and press Return or Enter. When prompted for user name and
password press Return twice, and the Main Menu on the DL3800 should
appear. The default unit number is 0.
Terminal Configuration
Only change the conÞguration items listed below. Leave other options at
the factory default settings. Note that to make a change you need to press
the up and down arrow to highlight the item, press the space bar until
the desired option displays, then highlight CONFIRM and press Enter
before exiting the menu.
Unit Configuration
Select Configuration from the Main Menu. Select Unit Configuration.
Set the Time and Date. Set unit number to a number other than zero. Select
Confirm, then select EXIT to go back to the CONFIGURATION MENU.
DTE Configuration
ConÞgure the DTE interface for either V.35/RS449 or HSSI. For V.35/RS449
conÞguration set the clock to SCTE and Normal TD/RD clock. Set the DTE
loss condition for NONE. Select Confirm, then select EXIT to go back to the
CONFIGURATION MENU.