User guide

Front Panel Interface 5-25
5
The user can set the threshold value for Minor (MI) and Major (MJ) alarms,
where exceeding the Minor alarm threshold will generate an alarm report
and the exceeding a Major alarm threshold will actually cause a T1 line to
be automatically taken out of service.
Pressing the ENTER button when NET THRESHOLDS appears in the
display screen will start the menu and allow the user to scroll, using the
down or up arrow buttons, through the following options:
Table 5-6 NET THRESHOLD Options and Values
OPTION VALUE
CON CRCS 010
CON CRCS OFF
CON SES 010
CONSES ON
CON UAS 015
CON UAS OFF
15.MIN.MI.BPV 100
15.MIN.MJ.BPV 100
15.MIN.MJ.BPV OFF
15.MIN.MI.CRCS 100
15.MIN.MJ.CRCS 100
15.MIN.MJ.CRCS OFF
15.MIN.MI.ES 100
15.MIN.MJ.ES 100
15.MIN.MJ.ES OFF
15.MIN.MI.SES 100
15.MIN.MJ.SES 100
15.MIN.MJ.SES OFF
15.MIN.MI.UAS 100
15.MIN.MJ.UAS 100
15.MIN.MJ.UAS OFF
24.HR.MI.BPV 10
24.HR.MJ.BPV 10
24.HR.MJ.BPV OFF